Continuation: light barrier – Baumfolder Baumcut Programmable 26.4 User Manual
Page 33

K4 - 5
D1
D2
D3
D4
D5
D6
Display unit in the left-hand part of the light barrier (receiver side):
Continuation: Light Barrier
4.0 Manual Operation
Meaning of LEDs in display unit
D1
D2
D3
D4
D5
D6
Meaning
_________________________________________________________________
on
on
on
on
off
off
Protect. area „unobstructed“, light
reception excellent
off
on
on
on
off
off
Protect. area „unobstructed“, light
reception good
off
off
on
on
off
off
Protect. area „unobstructed“, light
reception just sufficient
on
on
off
off
on
on
Protect. area obstructed or a test is
performed
off
off
off
off
on
on
Protect. area has never been
unobstructed since Voltage ON
flashing
off
off
on
on
Error
Attention!
In the case of a breakdown of the display unit the safety function of the
light barrier will not be impaired!