SERVICING INSTRUCTIONS

ACCESS PANELS

Each warmer plate has a center stud which screws into a
bracket. Warmer plates on Canadian brewers are secured with a
nut. Remove button plug on bottom of brewer to access nut on
main warmer. Remove top panel to access nuts on top warmers.
Remove warmer plates by turning counter-clockwise.


Solenoid door is held by two screws and a retaining lip.

IN-LINE BREWERS:


Top panel is held by two screws at the rear and a retaining lip at
the front. Disconnect wires from the upper warmers.


Top front panel is held by two screws at the bottom and a
retaining lip at the top.


Bottom front panel is held by two clips under the warmer plate.

CAUTION:

SHOCK HAZARD

Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.

Fig. 9 Access Panels