SPECIFICATIONS

UNIT SIZE

RATINGS AND PERFORMANCE

Input Btuh*

Output Capacity (Btuh)

Nonweatherized ICS

AFUE

Nonweatherized ICS

Certified Temperature Rise Range

o

F

Certified External Static Pressure

Heat/Cool

Heating

Cooling

ELECTRICAL

Unit Volts-Hertz-Phase

115-60-1

Operating Voltage Range

Min-Max

104-127

Maximum Unit Amps
Maximum Wire Length (Measured 1 Way in Ft)
Minimum Wire Size

14

Maximum Fuse or Ckt Bkr Size (Amps)**

15

Transformer (24v)

40va

External Control

Heating

12va

Power Available

Cooling

35va

Air Conditioning Blower Relay

Standard

CONTROLS

Limit Control

SPST

Heating Blower Control

Solid-State Time Operation

Burners (Monoport)
Gas Connection Size

1/2-in. NPT

GAS CONTROLS

Gas Valve (Redundant)

White Rodgers

Min Inlet Pressure (In. wc)

4.5 (Natural Gas)

Max Inlet Pressure (In. wc)

13.6 (Natural Gas)

Ignition Device

Hot Surface

BLOWER DATA

Direct-Drive Motor HP (PSC)
Motor Full Load Amps
RPM (Nominal)-Speeds
Blower Wheel Diameter x Width (In.)

Airflow CFM

024045

35,000
34,000

80.0

30-60

0.10/0.50

920
845

5.6

47

1/5
2.9

1075-3

10 x 6

42,000

44,000

2

036045

36,000
34,000

80.0

20-50

0.10/0.50

1250
1160

7.0

39

1/3
5.2

1075-4

10 x 6

42,000

44,000

2

024070

53,000
51,000

80.0

40-70

0.12/0.50

720
900

5.0

52

1/5
2.9

1075-4

10 x 6

63,000

66,000

3

036070

54,000
51,000

80.0

30-60

0.12/0.50

1195
1200

6.7

40

1/3
5.2

1075-4

10 x 6

63,000

66,000

3

042090

71,000
68,000

80.0

40-70

0.15/0.50

1375
1385

8.1

34

1/3
5.2

1075-4

10 x 8

84,000

88,000

4

048090

71,000
68,000

80.0

30-60

0.15/0.50

1505
1720

9.8

28

1/2
7.9

1075-4

10 x 10

84,000

88,000

4

-4-

311JAV Upflow; all 311AAV

311JAV Upflow; all 311AAV
311JAVDownflow/Horizontal

311JAVDownflow/Horizontal

048070

53,000
51,000

80.0

25-55

0.12/0.50

1450
1530

9.4

29

1/2
5.2

1075-4

11 x 8

63,000

66,000

3

*

Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National
Fuel Gas Code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 ft to 4500 ft above sea level.

Capacity in accordance with U.S. Government DOE test procedures.

Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter
is required for each return-air supply. An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.

ICS-Isolated Combustion System

** Time-delay type is recommended.

N/A-Not Applicable