CONTROLS-THERMOSTATS AND ZONING

THERMOSTAT- NON-PROGRAMMABLE

Auto Changeover,

o

F/

o

C, 1-Stage Heat/1-Stage Cool - TSTATBBNAC01-B

Auto Changeover,

o

F/

o

C, 2-Stage Heat/1-Stage Cool - TSTATBBNHP01-B

Auto Changeover,

o

F/

o

C, 2-Stage Heat/2-Stage Cool - TSTATBBN2S01-B

in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode

Air Conditioner, 1-Stage Heat/1-Stage Cool, Manual Changeover,

o

F/

o

C - TSTATBBBAC01

Heat Pump, 2-Stage Heat/1-Stage Cool, Manual Changeover,

o

F/

o

C - TSTATBBBHP01 *

THERMOSTAT- PROGRAMMABLE

Auto Changeover, 7-Day Programmable,

o

F/

o

C, 1-Stage Heat/1-Stage Cool - TSTATBBPAC01-B

Auto Changeover, 7-Day Programmable,

o

F/

o

C, 2-Stage Heat/1-Stage Cool - TSTATBBPHP01-B

Auto Changeover, 7-Day Programmable,

o

F/

o

C, 2-Stage Heat/2-Stage Cool - TSTATBBP2S01-B

in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode

Dual Fuel Thermostat, includes Outdoor Air Temperature Sensor - TSTATBBPDF01-B *

Thermidistat Control - Non-Programmable/Programmable Thermostat - TSTATBBPRH01-B

*

with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air

Temperature Sensor.)

ZONING- 2-ZONE

ZONEBB2KIT01-B, ZONEKIT2ZBDP

ZONING- 4-ZONE

ZONEBB4KIT01-B

ZONING- 8-ZONE

ZONEBB8KIT01-B

*

Do not use in zoning heat pump applications.

-3-

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

Cette fournaise à air pulsé est équipée

pour utilisation avec gaz naturel et altitudes

comprises entre 0-3,050m (0-10,000 pi).

Utiliser une trousse de conversion, fournie par

le fabricant, pour passer au gaz propane ou pour

certaines installations au gaz naturel.

Cette fournaise est prévue pour être

installée dans un bâtiment construit sur place.

Cette fournaise peut être installée sur

un plancher combustible dans une alcôve ou

dans un garde-robe en respectant le minimum

d'espace libre des matériaux combustibles, tel

qu'indiqué sur le diagramme.

.

Cette fournaise peut être utilisée avec un

conduit d´évacuation de Type B-1 ou connectée

au conduit commun d´autres appareils à gaz.

.

DISTANCE MINIMALE EN POUCES AUX CONSTRUCTIONS COMBUSTIBLES

INSTALLATION

327590-101 REV. B

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS

DE CONSTRUCTION COMBUSTIBLES

Ø

*

Installation on non-combustible floors only.
For Installation on combustible flooring only when installed on special base, Part No. KGASB0201ALL,

Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.

18 inches front clearance required for alcove.
Indicates supply or return sides when furnace is in the horizontal position. Line contact only permissible

between lines formed by intersections of the Top and two Sides of the furnace jacket, and building joists,
studs or framing.

Clearance in inches

Dégagement (po).

Clearance arrows

do not change with

furnace orientation.

Les fléches de dégagement

ne changent pas avec

l´orientation de la fournaise.

BO

TT

O

M

D

ES

SO

U

S

0"

3"

0"

0"

1"

0"

30"

MIN

S I

DE

C Ô

T É

F R

O N

T

A V

A N

T

B

C K

A R

R I È

A

E

R

S E

R VI

E

C

EN

TR

T

E

N

E

I

V

A

N

A

T

FR

ON

T

S I

E

C Ô

T È

F O

U

U

F

R N

A C S

E E

I

A

R N

Ø

Vent Clearance to combustibles:

For Single Wall vents 6 inches (6 po).

For Type B-1 vent type 1 inch (1 po).

Dégagement de l´évent avec combustibles:

Pour conduit d´évacuation à paroi simple 6 po (6 inches).

Pour conduit d´évacuation de Type B-1 1 po (1 inch).

T

O

P

/ P

LE

N

U

M

D

ES

SU

S

/ C

H

AM

BR

ED

'A

IR

D

*

*

Cette fournaise est approuvée pour l´installation HORIZONTALE

et la circulation d´air VERS LE HAUT et VERS LE BAS.

This furnace is approved for UPFLOW, DOWNFLOW, and

HORIZONTAL installations.

MIN

Ø

*

Pour l´installation sur plancher non combustible seulement.
Pour l´installation sur un plancher combustible seulement quand on utilise la base spéciale, pièce

n KGASB0201ALL, l´ensemble serpentin, pièce n CD5 ou CK5, ou le carter de serpentin, pièce
n KCAKC.

Dans une alcôve, on doit maintenir un dégagement à l´avant de 18 po (450 mm).
La position indiquée concerne le côté d´entrée ou de retour

quand la fournaise est dans la

position horizontale.

Le contact n´est permis qu´entre les lignes formées par les intersections du dessus et des

deux côtés de la chemise de la fournaise et les solives, montant sous cadre de charpente.

POUR LA POSITION COURANT DESCENDANT:

DOWNFLOW POSITIONS:

This forced air furnace is equipped for use with

natural gas at altitudes 0-10,000 ft (0-3,050m).

An accessory kit, supplied by the

manufacturer,shall be used to convert to propane

gas use or may be required for some natural gas

applications.

This furnace is for indoor installation in a

building constructed on site.

This furnace may be installed on combustible

flooring in alcove or closet at minimum clearance

as indicated by the diagram from combustible

material .

This furnace may be used with a Type B-1 Vent