Accessory Description and Usage (Listed Alphabetically) (Continued)

14. Winter Start Control
This control is designed to alleviate nuisance opening of the

low--pressure switch by bypassing it for the first 3 minutes of
operation.

ELECTRICAL DATA

UNIT

SIZE

V/PH

OPER

VOLTS*

COMPR

FAN

MCA

MIN WIRE

SIZE{

MIN WIRE

SIZE{

MAX

LENGTH

(FT)}

MAX

LENGTH

(FT)}

MAX

FUSE**

or CKT

BRK

AMPS

MAX

MIN

LRA

RLA

FLA

60° C

75° C

60° C

75° C

18

208/230/1

253

197

48.0

9.0

0.5

11.7

14

14

67

64

15

24

58.3

13.5

0.75

17.6

14

14

45

43

25

30

64.0

12.8

0.75

16.8

14

14

47

45

25

36

77.0

14.1

1.4

19.0

12

12

66

63

30

42

112.0

17.9

1.1

23.5

12

12

53

51

40

48

109.0

19.9

1.4

26.2

10

10

76

73

40

60

134.0

26.4

1.2

34.2

8

8

91

86

50

* Permissible limits of the voltage range at which the unit will operate satisfactorily
{

If wire is applied at ambient greater than 30˚ C (86˚ F), consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non---metallic---sheathed cable

(NM), trade name ROMEX, shall be that of 60˚ C (140˚ F) conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60

or 75˚ C (140 or 167˚ C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables

of the NEC (ANSI/NFPA 70).

}

Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.

** Time---Delay fuse.

FLA --- Full Load Amps

LRA --- Locked Rotor Amps

MCA --- Minimum Circuit Amps

RLA --- Rated Load Amps

NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.

All motors/compressors contain internal overload protection.

A--WEIGHTED SOUND POWER (DBA)

UNIT

SIZE

STANDARD

RATING

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

125

250

500

1000

2000

4000

8000

18

76

52.0

61.0

67.0

70.5

67.5

63.5

56.5

24

76

56.5

64.0

67.5

69.5

67.0

65.0

60.5

30

76

55.0

63.5

69.0

72.0

69.0

64.5

59.5

36

76

58.5

64.0

68.0

69.5

66.0

62.5

55.0

42

78

57.5

65.0

71.0

73.0

70.5

67.5

62.5

48

78

59.5

67.0

72.5

73.0

70.0

67.0

62.5

60

78

53.5

61.0

67.5

74.5

68.5

62.5

61.0

A--WEIGHTED SOUND POWER (DBA) WITH ACCESSORY SOUND HOOD

UNIT

SIZE

STANDARD

RATING

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

125

250

500

1000

2000

4000

8000

18

74

50.0

61.5

64.5

66.5

64.0

61.0

54.5

24

75

58.0

65.5

69.0

70.5

68.0

65.0

59.0

30

76

56.5

64.0

69.5

71.5

69.0

64.5

58.0

36

76

58.5

64.5

68.5

69.5

67.0

63.5

58.5

42

77

57.5

65.0

70.5

72.0

70.0

67.0

62.0

48

77

59.5

67.0

72.0

72.0

69.5

66.5

62.0

60

77

53.0

61.0

66.5

73.0

66.0

60.5

57.5

CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)

UNIT SIZE--- VOLTAGE & SERIES

REQUIRED SUBCOOLING (_F)

018---A

8

024---A

13

030---A

16

036---A

16

042---A

10

048---A

17

060---A

11

113A