Combination ratings continued – Bryant AIR CONDITIONER WITH PURONR 113A User Manual
Page 14
14
COMBINATION RATINGS CONTINUED
Unit Size ---
Voltage &
Series
Indoor
Model
Total Cap.
BTUH
Factory
Supplied
Enhancement
SEER
EER
Furnace
Model
Standard
Rating
TDR{
048---A
CNPH*4821A**
45,000
TDR&TXV
13.50
11.20
315(A,J)AV048090
CNPH*4821A**
45,500
TDR&TXV
13.50
11.20
315(A,J)AV060110
CNPH*6024A**
47,000
TXV
13.20
11.00
CNPH*6024A**
46,000
TDR&TXV
13.50
11.20
355AAV060080
CNPH*6024A**
46,000
TDR&TXV
13.50
11.20
355AAV060100
CNPH*6024A**
46,000
TDR&TXV
13.50
11.20
315(A,J)AV048090
CNPH*6024A**
46,000
TDR&TXV
13.50
11.20
315(A,J)AV060110
CNPF*4818A**
45,000
TXV
13.00
11.00
CSPH*4812A**
46,000
TXV
13.00
11.00
CSPH*4812A**
45,000
TDR&TXV
13.20
11.00
355AAV060080
CSPH*4812A**
45,500
TDR&TXV
13.50
11.20
315(A,J)AV048090
CSPH*6012A**
47,000
TXV
13.20
11.00
CSPH*6012A**
46,000
TDR&TXV
13.50
11.20
355AAV060080
CSPH*6012A**
46,000
TDR&TXV
13.50
11.20
315(A,J)AV048090
FX4CN(B,F)048
47,000
TDR&TXV
13.50
11.20
FX4CN(B,F)060
47,500
TDR&TXV
14.00
11.50
FV4BNF005
46,500
TDR&TXV
14.00
11.50
FV4BNB006
47,000
TDR&TXV
14.00
11.70
FY4ANF048
46,000
TDR&TXV
13.00
11.00
FY4ANB060
46,500
TDR&TXV
13.20
11.00
060---A
CAP**6021A**
56,500
TXV
13.00
11.00
CAP**6021A**
56,000
TDR&TXV
13.20
11.00
315(A,J)AV060110
*CAP**6024A**
57,500
TXV
13.00
11.00
CAP**6024A**
56,500
TDR&TXV
13.20
11.00
315(A,J)AV066135
CAP**6024A**
56,500
TDR&TXV
13.50
11.20
315(A,J)AV066155
CNPV*6024A**
57,000
TXV
13.00
11.00
CNPV*6024A**
56,000
TDR&TXV
13.50
11.00
315(A,J)AV066135
CNPV*6024A**
56,500
TDR&TXV
13.50
11.20
315(A,J)AV066155
CNPH*6024A**
57,000
TXV
13.00
11.00
CNPH*6024A**
56,000
TDR&TXV
13.50
11.20
315(A,J)AV066135
CNPH*6024A**
56,500
TDR&TXV
13.50
11.20
315(A,J)AV066155
CSPH*6012A**
57,500
TXV
13.00
11.00
CSPH*6012A**
56,500
TDR&TXV
13.20
11.00
315(A,J)AV060110
CSPH*6012A**
56,500
TDR&TXV
13.50
11.20
315(A,J)AV066135
CSPH*6012A**
56,500
TDR&TXV
13.50
11.20
315(A,J)AV066155
FX4CN(B,F)060
58,000
TDR&TXV
13.20
11.00
FV4BNB006
57,000
TDR&TXV
13.50
11.20
FY4ANB060
56,500
TDR&TXV
13.00
11.00
* Tested combination
{
In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay
TXV — Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
113A