ACCESSORY THERMOSTATS
THERMOSTAT / SUBBASE PKG.
DESCRIPTION
TSTATBBPRH01---B
Thermidistat Control --- Programmable / Non---Programmable Thermostat with Humidity control
TSTATBBPAC01---B
Thermostat --- Auto Changeover, 7---Day Programmable, _F/_C, 1---Stage Heat, 1---Stage Cool
TSTATBBNAC01---C
Thermostat --- Auto Changeover, Non---Programmable, _F/_C, 1---Stage Heat, 1---Stage Cool
TSTATBBBAC01---B
Builder’s Thermostat --- Manual Changeover, Non---Programmable, _F/_C, 1---Stage Heat, 1---Stage Cool
TSTATBBSEN01---B
Outdoor Air Temperature Sensor
TSTATXXBBP01
Backplate for Builder’s Thermostat
TSTATXXNBP01
Backplate for Non---Programmable Thermostat
TSTATXXPBP01
Backplate for Programmable Thermostat
TSTATXXCNV10
Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack
ACCESSORIES
KIT NUMBER
DESCRIPTION
Size --- Voltage & Series
18---30
24---30
30---30
36---30
42---30
48---30
60---30
KAAFT0101AAA
FREEZE THERMOSTAT
X
X
X
X
X
X
X
KAATD0101TDR
TIME DELAY RELAY
X
X
X
X
X
X
X
KAAWS0101AAA
WINTER START
X
X
X
X
X
X
X
KSALA0301410
LOW AMBIENT PSW
X
X
X
X
X
X
X
KSALA0601AAA
MOTORMASTER 230V
X
X
X
X
X
X
X
HC32GE234
MOTOR FAN BALL BEARING
X
HC34GE239
MOTOR FAN BALL BEARING
X
X
HC40GE226
MOTOR FAN BALL BEARING
X
X
HC38GE219
MOTOR FAN BALL BEARING
X
HC40GE228
MOTOR FAN BALL BEARING
X
KSAHS1701AAA
HARD START (CAP / RELAY)
X
X
X
X
X
X
X
KSACY0101AAA
CYCLE PROTECTOR
X
X
X
X
X
X
X
KSASF0101AAA
SUPPORT FEET
X
X
X
X
X
X
X
KAACS0201PTC
START ASSIST PTC
X
X
X
X
X
X
X
KAACH1201AAA
CRANKCASE HTR
X
X
X
KAACH1401AAA
CRANKCASE HTR
X
X
X
X
KSATX0201PUR
TXV PURON HSO
X
X
X
KSATX0301PUR
TXV PURON HSO
X
X
KSATX0401PUR
TXV PURON HSO
X
KSATX0501PUR
TXV PURON HSO
X
KSASH1801COP
SOUND HOOD
X
X
X
X
KSASH0601COP
SOUND HOOD
X
X
KSASH2101COP
SOUND HOOD
X
KAALP0301PUR
LOW PRESSURE SWITCH
X
X
X
X
X
X
X
KAAHI0401PUR
HIGH PRESSURE SWITCH
X
X
X
X
X
X
X
ACCESSORY USAGE GUIDELINE
ACCESSORY
REQUIRED FOR LOW---AMBIENT
COOLING APPLICATIONS
(Below 55° F)
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 Ft.)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles)
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No
No
Accumulator
No
No
No
Compressor Start Assist Capacitor and Relay
Yes
Yes
No
Motor Master
®
Control or Low---ambient
Pressure Switch
Yes
No
No
Support Feet
Recommended
No
Recommended
Liquid Line Solenoid Valve
No
See Long---Line Ap-
plication Guideline
No
Ball Bearing Fan Motor
Yes{
No
No
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial, refer to Residential Split---System Longline Application Guideline.
{
Required for Low---Ambient Controller (full modulation feature) and MotorMasterr Control only.
113A