Fig. 9–furnace wiring diagram – Bryant Induced- Combustion 333BAV User Manual

Page 7

background image

Fig. 9–Furnace Wiring Diagram

A00357

RED

LS

FRS2

RE

D

RE

D

FRS1

(WHEN USED)

ALS2

DSS

OR

N

LGPS

YE

L

NOTE 9

LPS

NO

T

E

9

(W

HE

N U

S

E

D

)

RE

D

YEL

OR

N

(WHEN USED)

NOTE 7

ALS1

OR

N

SWITCH
1

2

HEAT
SET-UP
SWITCH
NORM
HI HT
LO HT

*

ON

OF

F

OF

F

ON

BLOWER-

OFF DELAY
(SEC.)

SWITCH

3

4

90 SEC

135 SEC

*

180 SEC
225 SEC

ON

OF

F

OFF

ON

2-STAGE

FURNACE
CONTROL

FACTORY

SETTINGS

12

3

4

ON

OF

F

3

2

1

BL

U

BLOWER-OFF DELAY

BLOWER-OFF DELAY
LOW-HEAT ONLY

HIGH-HEAT ONLY

*

RED

RED

ORN

W2

Com
24V

W/W1 Y/Y2

R

G

HUM

LED

S

M

TJ

TWIN

TEST

12

11

10

GR

N

/Y

E

L

BR

N

PL1

WH

T

BLK

GR

Y

YEL

3

2

1

9

87

WH

T

FS

E

BL

K

GRY

BRN

HPS

BRN

HI

P

BLU

M

IDM

HSI

GRN/YEL

ILK

JB

L1

WHT

PL6

RE

D

BL

K

WH

T

BL

K

WH

T

1

2

1

2

3

PL3

WHT

BLK

RED

PL2

PR1

PR2

L1

L2

COMMON

HI-COOL

HI-GAS

HEAT

EAC-2

EAC-1

LO-GAS

HEAT

SPARE

SEC1

FU1

SEC2

RED

BLU

BLWM

WHT

BLK

TRAN

RE

D

BLU

WH

T

BL

K

GV

C

FUSED DISCONNECT

SWITCH (WHEN REQ’D)

NOTE #1

BLK

WHT

L2

FU2

CONNECTION DIAGRAM

OR

N

16

YEL

BLU

BLK

BRN

RED

YE

L

YE

L

BLU

BLK

WH

T

BL

K

BL

K

BL

K

GR

N

BL

U

RE

D

RE

D

CFM
PER
TON

AC
HP

GAS

HEAT
TEMP

RISE

CONTINUOUS

-

FAN

CFM

COOL

SI

ZE

COOL

GR

Y

5
4

3
2
1

BLK

WHT

YEL

9

1

16

8

O

R

N

B

L

K

G

R

N

W

H

T

V

IO

B

L

K

R

E

D

B

RN

Y

E

L

Y

E

L

B

L

U

G

R

N

B

L

K

ORN

BL

U

Y1

O

YEL

AFS

BLU

RED

ORN

GRN

GRN

RED

BLU

A

B

C

D

14

DE

H

U

M

PL4

G

RN

/YE

L

PL8

PL9

NOTE 15

PL5

PL5

IND

PL7

1

SCH

EM

AT

IC

DI

A

G

R

A

M

(N

AT

URAL

GA

S

& PR

O

P

A

N

E)

LEGEND

AFS

AIRFLOW SELECTOR

ALS1

AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)

ALS2

AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)

BHI / LOR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BHT / CLR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLWM

BLOWER MOTOR, ICM2

+ -

CTL

=

CONTROL

-

PWR

=

POWER

BLWR

BLOWER MOTOR RELAY, SPST (N.O.)

CPU

MICROPROCESSOR AND CIRCUITRY

DSS

DRAFT SAFEGUARD SWITCH (N.C.)

EAC-1

ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)

EAC-2

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FRS1

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FRS2

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FSE

FLAME-PROVING SENSOR ELECTRODE

FU1

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED

FU2

FUSE, FIELD INSTALLED

GV

GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE

HPS

HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)

HPSR

HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)

HSI

HOT-SURFACE IGNITER (115 VAC)

HSIR

HOT-SURFACE IGNITOR RELAY, SPST (N.O.)

HUM

24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)

IDM

INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE

IDR

INDUCER MOTOR RELAY, SPST (N.O.)

IHI / LOR

INDUCER MOTOR SPEED CHANGE RELAY, SPDT

ILK

BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)

IND

INDUCTOR (NOTE 16)

JB

JUNCTION BOX

LED

LIGHT-EMITTING DIODE FOR STATUS CODES

LGPS

LOW GAS-PRESSURE SWITCH, SPST (N.O.)

LPS

LOW-HEAT PRESSURE SWITCH, SPST (N.O.)

LS

LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)

MGVR

MAIN GAS VALVE RELAY DPST (N.O.)

-

1 = VALVE

-

2 = HUMIDIFIER

N / A

NOT APPLICABLE

PL1

12-CIRCUIT CONNECTOR

PL2

9-CIRCUIT CONNECTOR

PL3

3-CIRCUIT IDM CONNECTOR

PL4

6-CIRCUIT CONNECTOR

PL5

1-CIRCUIT CONNECTOR (NOTE 16)

PL6

2-CIRCUIT HSI CONNECTOR

PL7

14-CIRCUIT CONNECTOR

PL8

5-CIRCUIT CONNECTOR

PL9

16-CIRCUIT CONNECTOR

SW1

HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)

*

SW2

LOW-HAT-ONLY SWITCH, SPST (MANUAL)

*

SW3 & 4

BLOWER-OFF DELAY SETTING SWITCHES,

SPST (MANUAL)

*

TJ

TWINNING JUMPER,

SPDT(MANUAL CHANGE-OVER). (NOTE 17)

TRAN

TRANSFORMER-115VAC/24VAC

TWIN/TEST

1-CIRCUIT TWINNING BUSS CONNECTOR,

ALSO STATUS CODE RECALL. (NOTE 17)

JUNCTION

TERMINAL

CONTROL TERMINAL

FACTORY POWER WIRING (115VAC)

FACTORY CONTROL WIRING (24VAC)

FIELD POWER WIRING (115VAC)

FIELD CONTROL WIRING (24VAC)

CONDUCTOR ON CONTROL

FIELD WIRING SCREW TERMINAL

FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

AIRFLOW SELECTOR JUMPER PINS

AIRFLOW SELECTOR FACTORY SETTING

NOTES:

1. Use only copper wire between the disconnect switch and the furnace.
2. If any of the original wire, must be replaced, use the same or equivalent type.
3. Inducer (IDM) motor contains internal auto-reset thermal overload switch.
4. Blower motor airflow selections are for nominal conditions. See Installation

Instructions for details on optimum airflow selections.

5. Blower motor (BLWM) is locked-rotor overload protected by redundant

electronic control circuits. Restart is attempted every 15 seconds for 2 minutes,
after which it locks OFF. Reset by turning OFF all control and/or power inputs.

6. Replace only with a 3-AMP fuse.
7. Auxiliary limit switches (ALS1 & 2) used on some horizontal and some

downflow models.

8. This wire must be connected to furnace sheet metal for control to prove flame.
9. Factory connected when LGPS not used.
10. Symbols are an electrical representation only.
11. BLOWER-ON DELAY: Gas heating 45 seconds, Cooling/Heat Pump 2 sec.
12. Cooling/Heat Pump BLOWER-OFF DELAY is 90 seconds.
13. IGNITION-LOCKOUT will occur after four consecutive unsuccessful

trials-for-ignition. Control will automatically reset after three hours.

14. Control must be grounded at pin 10 of 12-pin connector.
15. Inductor is used on 060 or

-

20 cooling airflow size furnaces only.

PL5 connectors are joined without IND on other furnace sizes.

16. Twinning is not permitted with ICM2

+

blower motors. Keep twinning jumper in

MASTER position.

17. Terminals (HI-COOL, HI-GAS-HEAT, and LO-GAS-HEAT) are not used for

ICM2

+

BLWM. Do not remove electrical insulators.

COMPONENT TEST

To initiate the component test sequence with no thermostat inputs and
with all inducer Post-Purge and Blower-Off Delay periods completed,
short the "TWIN/TEST" terminal to the "

C

OM" terminal for about two

seconds. The control will turn ON the inducer motor Low-Speed, inducer
motor High-Speed, HSI, blower motor Continuous-Fan Speed, blower
motor High-Gas-Heat Speed, and blower motor High-Cool Speed for
7-15 seconds each. Neither the gas valve nor the humidifier will be
turned ON.

HI

M-HI

M-LO

LO

315

350

400

AC

HP

EFFY

HP

CMFT

MID

HI

M-HI

MED

LO

HI

WHT

WHT

GRN

NOTE 4

NOTE 17

32

2

293-101 RE

V.

F

L1

BLWR

TO 115VAC FIELD DISCONNECT SWITCH

NOTE 1

EQUIPMENT

GROUND

LO-GAS-HEAT

HI-GAS-HEAT

SPARE

COMMON

HSIR

EAC-1 EAC-2

PR2

115VAC

PR1

TRAN

24VAC

IDR

L2

ILK

BHI / LOR

BHT / CLR

IHI / LOR

SEC1

FU1

NOTE 6

HI-COOL

SEC2

LS

ALS1

DSS

ALS2

FRS1

(WHEN

USED)

FRS2

N/A

12

2

3

MGVR-2

9

6

NOTE 9

(WHEN USED)

TWIN
TEST

SLAVE

MASTER

W/W1

R

HUM

W2

Y/Y2

G

MGVR-1

NOTE 9

HPS

5

4

1

10

7
8 N/A

N/A

FSE

11

HI

M

P

C

NOTE 8

PL1

CPU

LGPS

SW1

GV

SEE BLWM-CTL

PL5

PL8

BLWM-PWR

PL5

IND

NOTE 15

5
4
3
2
1

Y

Y2

24

VAC

G

W2

5

6

4

1

2

PL4

BLWR

BHT / CLR

JUMPER

TJ

TWINNING

C1

3

BHI / LOR

PL7

10

12

13

2

SW4

SW3

SW

2

14

9

8

6

5

11

1

3

4

7

HI

M-HI

M-LO

LO

400

350

315

AC

HP

EFFY

HP

CMFT

HI

M-HI

MID

HI

MED

LO

CFM

PER
TON

AC
HP

GAS

HEAT

TEMP

RISE

CONTINUOUS

-

FAN

CFM

COOL

SIZE

A

B

C

D

C

OM

D

EH

U

M

COOL

AFS

NOTE

16

NOTE 4

LPS

NO

TE

17

Connect VIO wire to pin
A, B, C, or D as
designated on furnace
rating plate as "PIN".

(WHEN USED)

SPARE

GRN/YEL

GND

LO

8

7

4

PL3

N/A

N/A

2

6

5

1

HPSR

COM

HI

3

2
1

PL6

ID

M

PL2

9

2

HSI

1

3

GRN/YEL

4

YE

L

ORN

VIO

3

3

BLK

BRN

4

3

3

4

3

3

BK/PWM

10

OUT

+

16

OUT

-

8

EM/W2

13

R

12

C1

1

C2

3

W/W1

2

ADJ

7

G

15

HEAT

11

Y/Y2

14

O

9

COOL

5

DELAY

4

Y1

6

Y1

O

BLWM-CTL

PL9


7