Fig. 9–furnace wiring diagram – Bryant Induced- Combustion 333BAV User Manual
Page 7

Fig. 9–Furnace Wiring Diagram
A00357
RED
LS
FRS2
RE
D
RE
D
FRS1
(WHEN USED)
ALS2
DSS
OR
N
LGPS
YE
L
NOTE 9
LPS
NO
T
E
9
(W
HE
N U
S
E
D
)
RE
D
YEL
OR
N
(WHEN USED)
NOTE 7
ALS1
OR
N
SWITCH
1
2
HEAT
SET-UP
SWITCH
NORM
HI HT
LO HT
*
ON
OF
F
OF
F
ON
BLOWER-
OFF DELAY
(SEC.)
SWITCH
3
4
90 SEC
135 SEC
*
180 SEC
225 SEC
ON
OF
F
OFF
ON
2-STAGE
FURNACE
CONTROL
FACTORY
SETTINGS
12
3
4
ON
OF
F
3
2
1
BL
U
BLOWER-OFF DELAY
BLOWER-OFF DELAY
LOW-HEAT ONLY
HIGH-HEAT ONLY
*
RED
RED
ORN
W2
Com
24V
W/W1 Y/Y2
R
G
HUM
LED
S
M
TJ
TWIN
TEST
12
11
10
GR
N
/Y
E
L
BR
N
PL1
WH
T
BLK
GR
Y
YEL
3
2
1
9
87
WH
T
FS
E
BL
K
GRY
BRN
HPS
BRN
HI
P
BLU
M
IDM
HSI
GRN/YEL
ILK
JB
L1
WHT
PL6
RE
D
BL
K
WH
T
BL
K
WH
T
1
2
1
2
3
PL3
WHT
BLK
RED
PL2
PR1
PR2
L1
L2
COMMON
HI-COOL
HI-GAS
HEAT
EAC-2
EAC-1
LO-GAS
HEAT
SPARE
SEC1
FU1
SEC2
RED
BLU
BLWM
WHT
BLK
TRAN
RE
D
BLU
WH
T
BL
K
GV
C
FUSED DISCONNECT
SWITCH (WHEN REQ’D)
NOTE #1
BLK
WHT
L2
FU2
CONNECTION DIAGRAM
OR
N
16
YEL
BLU
BLK
BRN
RED
YE
L
YE
L
BLU
BLK
WH
T
BL
K
BL
K
BL
K
GR
N
BL
U
RE
D
RE
D
CFM
PER
TON
AC
HP
GAS
HEAT
TEMP
RISE
CONTINUOUS
-
FAN
CFM
COOL
SI
ZE
COOL
GR
Y
5
4
3
2
1
BLK
WHT
YEL
9
1
16
8
O
R
N
B
L
K
G
R
N
W
H
T
V
IO
B
L
K
R
E
D
B
RN
Y
E
L
Y
E
L
B
L
U
G
R
N
B
L
K
ORN
BL
U
Y1
O
YEL
AFS
BLU
RED
ORN
GRN
GRN
RED
BLU
A
B
C
D
14
DE
H
U
M
PL4
G
RN
/YE
L
PL8
PL9
NOTE 15
PL5
PL5
IND
PL7
1
SCH
EM
AT
IC
DI
A
G
R
A
M
(N
AT
URAL
GA
S
& PR
O
P
A
N
E)
LEGEND
AFS
AIRFLOW SELECTOR
ALS1
AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)
ALS2
AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)
BHI / LOR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BHT / CLR BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLWM
BLOWER MOTOR, ICM2
+ -
CTL
=
CONTROL
-
PWR
=
POWER
BLWR
BLOWER MOTOR RELAY, SPST (N.O.)
CPU
MICROPROCESSOR AND CIRCUITRY
DSS
DRAFT SAFEGUARD SWITCH (N.C.)
EAC-1
ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)
EAC-2
ELECTRONIC AIR CLEANER CONNECTION (COMMON)
FRS1
FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FRS2
FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FSE
FLAME-PROVING SENSOR ELECTRODE
FU1
FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED
FU2
FUSE, FIELD INSTALLED
GV
GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE
HPS
HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)
HPSR
HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)
HSI
HOT-SURFACE IGNITER (115 VAC)
HSIR
HOT-SURFACE IGNITOR RELAY, SPST (N.O.)
HUM
24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)
IDM
INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE
IDR
INDUCER MOTOR RELAY, SPST (N.O.)
IHI / LOR
INDUCER MOTOR SPEED CHANGE RELAY, SPDT
ILK
BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)
IND
INDUCTOR (NOTE 16)
JB
JUNCTION BOX
LED
LIGHT-EMITTING DIODE FOR STATUS CODES
LGPS
LOW GAS-PRESSURE SWITCH, SPST (N.O.)
LPS
LOW-HEAT PRESSURE SWITCH, SPST (N.O.)
LS
LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)
MGVR
MAIN GAS VALVE RELAY DPST (N.O.)
-
1 = VALVE
-
2 = HUMIDIFIER
N / A
NOT APPLICABLE
PL1
12-CIRCUIT CONNECTOR
PL2
9-CIRCUIT CONNECTOR
PL3
3-CIRCUIT IDM CONNECTOR
PL4
6-CIRCUIT CONNECTOR
PL5
1-CIRCUIT CONNECTOR (NOTE 16)
PL6
2-CIRCUIT HSI CONNECTOR
PL7
14-CIRCUIT CONNECTOR
PL8
5-CIRCUIT CONNECTOR
PL9
16-CIRCUIT CONNECTOR
SW1
HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)
*
SW2
LOW-HAT-ONLY SWITCH, SPST (MANUAL)
*
SW3 & 4
BLOWER-OFF DELAY SETTING SWITCHES,
SPST (MANUAL)
*
TJ
TWINNING JUMPER,
SPDT(MANUAL CHANGE-OVER). (NOTE 17)
TRAN
TRANSFORMER-115VAC/24VAC
TWIN/TEST
1-CIRCUIT TWINNING BUSS CONNECTOR,
ALSO STATUS CODE RECALL. (NOTE 17)
JUNCTION
TERMINAL
CONTROL TERMINAL
FACTORY POWER WIRING (115VAC)
FACTORY CONTROL WIRING (24VAC)
FIELD POWER WIRING (115VAC)
FIELD CONTROL WIRING (24VAC)
CONDUCTOR ON CONTROL
FIELD WIRING SCREW TERMINAL
FIELD GROUND
EQUIPMENT GROUND
FIELD SPLICE
PLUG RECEPTACLE
AIRFLOW SELECTOR JUMPER PINS
AIRFLOW SELECTOR FACTORY SETTING
NOTES:
1. Use only copper wire between the disconnect switch and the furnace.
2. If any of the original wire, must be replaced, use the same or equivalent type.
3. Inducer (IDM) motor contains internal auto-reset thermal overload switch.
4. Blower motor airflow selections are for nominal conditions. See Installation
Instructions for details on optimum airflow selections.
5. Blower motor (BLWM) is locked-rotor overload protected by redundant
electronic control circuits. Restart is attempted every 15 seconds for 2 minutes,
after which it locks OFF. Reset by turning OFF all control and/or power inputs.
6. Replace only with a 3-AMP fuse.
7. Auxiliary limit switches (ALS1 & 2) used on some horizontal and some
downflow models.
8. This wire must be connected to furnace sheet metal for control to prove flame.
9. Factory connected when LGPS not used.
10. Symbols are an electrical representation only.
11. BLOWER-ON DELAY: Gas heating 45 seconds, Cooling/Heat Pump 2 sec.
12. Cooling/Heat Pump BLOWER-OFF DELAY is 90 seconds.
13. IGNITION-LOCKOUT will occur after four consecutive unsuccessful
trials-for-ignition. Control will automatically reset after three hours.
14. Control must be grounded at pin 10 of 12-pin connector.
15. Inductor is used on 060 or
-
20 cooling airflow size furnaces only.
PL5 connectors are joined without IND on other furnace sizes.
16. Twinning is not permitted with ICM2
+
blower motors. Keep twinning jumper in
MASTER position.
17. Terminals (HI-COOL, HI-GAS-HEAT, and LO-GAS-HEAT) are not used for
ICM2
+
BLWM. Do not remove electrical insulators.
COMPONENT TEST
To initiate the component test sequence with no thermostat inputs and
with all inducer Post-Purge and Blower-Off Delay periods completed,
short the "TWIN/TEST" terminal to the "
C
OM" terminal for about two
seconds. The control will turn ON the inducer motor Low-Speed, inducer
motor High-Speed, HSI, blower motor Continuous-Fan Speed, blower
motor High-Gas-Heat Speed, and blower motor High-Cool Speed for
7-15 seconds each. Neither the gas valve nor the humidifier will be
turned ON.
HI
M-HI
M-LO
LO
315
350
400
AC
HP
EFFY
HP
CMFT
MID
HI
M-HI
MED
LO
HI
WHT
WHT
GRN
NOTE 4
NOTE 17
32
2
293-101 RE
V.
F
L1
BLWR
TO 115VAC FIELD DISCONNECT SWITCH
NOTE 1
EQUIPMENT
GROUND
LO-GAS-HEAT
HI-GAS-HEAT
SPARE
COMMON
HSIR
EAC-1 EAC-2
PR2
115VAC
PR1
TRAN
24VAC
IDR
L2
ILK
BHI / LOR
BHT / CLR
IHI / LOR
SEC1
FU1
NOTE 6
HI-COOL
SEC2
LS
ALS1
DSS
ALS2
FRS1
(WHEN
USED)
FRS2
N/A
12
2
3
MGVR-2
9
6
NOTE 9
(WHEN USED)
TWIN
TEST
SLAVE
MASTER
W/W1
R
HUM
W2
Y/Y2
G
MGVR-1
NOTE 9
HPS
5
4
1
10
7
8 N/A
N/A
FSE
11
HI
M
P
C
NOTE 8
PL1
CPU
LGPS
SW1
GV
SEE BLWM-CTL
PL5
PL8
BLWM-PWR
PL5
IND
NOTE 15
5
4
3
2
1
Y
Y2
24
VAC
G
W2
5
6
4
1
2
PL4
BLWR
BHT / CLR
JUMPER
TJ
TWINNING
C1
3
BHI / LOR
PL7
10
12
13
2
SW4
SW3
SW
2
14
9
8
6
5
11
1
3
4
7
HI
M-HI
M-LO
LO
400
350
315
AC
HP
EFFY
HP
CMFT
HI
M-HI
MID
HI
MED
LO
CFM
PER
TON
AC
HP
GAS
HEAT
TEMP
RISE
CONTINUOUS
-
FAN
CFM
COOL
SIZE
A
B
C
D
C
OM
D
EH
U
M
COOL
AFS
NOTE
16
NOTE 4
LPS
NO
TE
17
Connect VIO wire to pin
A, B, C, or D as
designated on furnace
rating plate as "PIN".
(WHEN USED)
SPARE
GRN/YEL
GND
LO
8
7
4
PL3
N/A
N/A
2
6
5
1
HPSR
COM
HI
3
2
1
PL6
ID
M
PL2
9
2
HSI
1
3
GRN/YEL
4
YE
L
ORN
VIO
3
3
BLK
BRN
4
3
3
4
3
3
BK/PWM
10
OUT
+
16
OUT
-
8
EM/W2
13
R
12
C1
1
C2
3
W/W1
2
ADJ
7
G
15
HEAT
11
Y/Y2
14
O
9
COOL
5
DELAY
4
Y1
6
Y1
O
BLWM-CTL
PL9
—
7
—