Page 2 of 7


To remove or to
insert the cable:
• Unscrew the retaining

nut;

• Pass the cable through

the grommet and the
retaining nut.

• Tighten the retaining nut.


Opening the sensor

Closing the sensor










• Loosen the retaining nut
until the cable slides easily into the

grommet;

• Partially unscrew the 2 front cover

screws;

• Pull out the front cover with the 2

front cover screws.

• Connect the quick disconnect terminal block to the main

electronic circuit;

• Slide the main electronic circuit into the 2 housing slot

guides;

• Gently push the front cover and make sure that the external

housing is properly seated (front cover must be flush with
housing).

• Screw the 2 front cover screws and tighten the retaining nut.

Ceiling Mounting

Wall Mounting















Remark: The bold-type values give the minimum distance required to be able to fully adjust the sensor.


• Check that both locking collar

are at the same angle;

• Align the bracket slot to the

locking collar guide as shown.







WIRING

OPENING AND

CLOSING THE

SENSOR

SENSOR

DIMENSIONS

AND

MOUNTING

2.5 in

5 in

6.25 in

6.

5 i

n

6 i

n

3 in

5.5 in

6 in

5 in

6.25 in

BRACKET

MOUNTING

US Wire Color: Red Black White Green Yellow
12-24 VAC/DC COM NO NC
European Wire Color:
Brown Green White Yellow Gray