beautypg.com

Hazard defi nitions – Beckett CF1000 User Manual

Page 4

background image

4

Form 6104 BCF10-R06

Hazard defi nitions

Intended to bring special attention to information,

but not related to personal injury or property
damage.

NOTICE

Indicates a potentially
hazardous situation,

which, if not avoided, may result in person-
al injury or property damage.

Indicates a potentially
hazardous situation,

which, if not avoided, could result in death,
severe personal injury, and/or substantial
property damage.

Indicates an imminently
hazardous situation,

which, if not avoided, will result in death,
serious injury, or property damage.

Within the boundaries of the hazard warning, there will
be information presented describing consequences if the
warning is not heeded and instructions on how to avoid
the hazard.

To the Owner:

Thank you for purchasing a Beckett burner

for use

with your heating appliance. Please pay attention to the
Safety Warnings contained within this instruction manual.
Keep this manual for your records and provide it to your
qualifi ed service agency for use in professionally setting
up and maintaining your oil burner.

Your Beckett burner will provide years of effi cient opera-

tion if it is professionally installed and maintained by a
qualifi ed service technician. If at any time the burner does
not appear to be operating properly, immediately contact
your qualifi ed service agency
for consultation.

We recommend annual inspection/service of your oil

heating system by a qualifi ed service agency.

Agency approvals

UL listed to comply with ANSI/UL296 and certifi ed to
CSA B140.0.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and must be specifi ed at
time of order.

‰

‰

‰

Specifi cations

Fuels

U.S. #1 or #2 heating
oil only (ASTM D396)
Canada #1 stove oil or
#2 furnace oil only

Firing range

4.0 to 10.0 GPH

Motor

½ HP 3450 RPM
120/60 hz standard
6.5 amps @ 120 VAC

Optional voltages:
(60 hz or 50 hz)
• 240/1-PH
• 208/240/480/3-PH

Ignition Trans.

120V/12,000V

Housing

Cast aluminum

Fuel unit

100 - 300 PSIG

Oil nozzle

45° - 70° solid

Shipping wt.

75 lbs.

Dimensions

See Figure 7 (Page 10)

(See NOTICE on 50 hz motor applications.)

LISTED

(FUEL) BURNER

SERIAL NUMBER

050214-00000

Control Circ: 120V/60Hz 4.5A

Motor Circ: 120V/60Hz 4.0A

Model “XX”

Series (Fuel) Burner

R.W. Beckett Corp.

Elyria, Ohio

Made in the U.S.A.

For use with Group 8 . . .

MP 1192 XX000 R00

X
X
X
X
X
X

XX000 R00

050214-00000

MFR’S SETTINGS

R.W. Beckett Construction & Setting Data

R.W. Beckett Specifi cation
Number and Revision

Boiler Manufacturer and
Model, When Applicable

Additional Codes

General Model Information

Serial Number,Including Date Code

Rating Information

Approval Agency Symbols

Primary Group and Fuel

L0002