You will need:
n
A location that allows for proper exhaust installation.
See “Venting Requirements.”
n
A separate 30-amp circuit.
n
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (610 mm) of either side of the washer/
dryer. See “Electrical Requirements.”
n
A sturdy floor to support the washer/dryer weight (washer/
dryer, water, and load) of 500 lbs (226.8 kg).
n
A level floor with a maximum slope of 1" (25 mm) under entire
washer/dryer. Clothes may not tumble properly and automatic
sensor cycles may not operate correctly if washer/dryer is not
level. Installing on carpet is not recommended.
n
A water heater set to deliver 120°F (49°C) water to the washer.
n
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of 5–100 psi
(34.5–689.6 kPa).
The washer/dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Do not operate your washer in temperatures at or below 32ºF
(0ºC). Some water can remain in the washer and can cause
damage in low temperatures. See “Washer/Dryer Care” in the
Washer/Dryer Use and Care Guide for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the washer/dryer in garages, closets, mobile
homes, or sleeping quarters. Contact your local building
inspector.
Recessed area or closet installation
The spacing dimensions above are recommended for this
washer/dryer. This washer/dryer has been tested for spacing of
0" (0 mm) clearance on the sides. Recommended spacing should
be considered for the following reasons:
n
Additional spacing should be considered for ease of
installation and servicing.
n
Additional clearances might be required for wall, door, and
floor moldings.
n
Additional spacing on all sides of the washer/dryer is
recommended to reduce noise transfer.
n
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Mobile Home – Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
n
Metal exhaust system hardware, which is available for
purchase from your dealer.
n
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
LOCATION REQUIREMENTS
Select proper location for your washer to improve performance
and minimize noise and possible “washer walk.” Install your
washer in a basement, laundry room, closet, or recessed area.
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
Closet
door
Front
View