beautypg.com

Whirlpool LTE5243DQ User Manual

Page 13

background image

13

4-Wire Direct Wire Connection

IMPORTANT:

A 4-wire connection is required for mobile

homes and where local codes do not permit 3-wire

connections.

2.

Connect neutral ground wire and

neutral wire

A

B

C

D

Remove center terminal block screw (A). Remove neutral

ground wire (B) from external ground conductor screw (C).

Connect neutral ground wire (B) and place the hooked end

(hook facing right) of the neutral wire (D) (white or center

wire) of direct wire cable under the center screw (A) of the

terminal block. Squeeze hooked ends together. Tighten

screw.

Direct wire cable must have 5 ft. (1.52 m) of

extra length so washer/dryer may be moved

if needed.

Strip 5" (127 mm) of outer covering from end of cable,

leaving bare ground wire at 5" (127 mm). Cut 1

1

/

2

" (38 mm)

from remaining 3 wires. Strip insulation back 1" (25 mm).

Shape ends of wires into hooks.

When connecting to the terminal block, place the hooked end

of the wire under the screw of the terminal block (hook facing

right), squeeze hooked end together and tighten screw.

1"

(25 mm)

5"

(127 mm

)

1.

Prepare your 4-wire cable for direct

connection

4.

Connect other wires

Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).

Squeeze hooked ends together. Tighten screws.

5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.

Secure cover with hold-down screw.

7. You have completed your electrical connection. Now go to

“Venting Requirements.”

G

C

3.

Connect ground wire

Connect ground wire (green or bare) (G) of direct wire cable to

external ground conductor screw (C). Tighten screw.