3-Wire Direct Wire Connection

IMPORTANT: Use where local codes permit connecting

cabinet-ground conductor to neutral wire.

A

D

2.

Connect neutral wire

Remove center terminal block screw (A). Place the hooked

end of the neutral wire (D) (white or center wire) of direct wire

cable under the center screw of terminal block (A) (hook facing

right). Squeeze hooked end together. Tighten screw

Direct wire cable must have 5 ft. (1.52 m) of

extra length so washer/dryer may be moved

if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from

end of cable. Strip insulation back 1" (25 mm).

If using 3-wire cable with ground wire, cut bare

wire even with outer covering. Shape wire ends into hooks.

When connecting to the terminal block, place the hooked end

of the wire under the screw of the terminal block (hook facing

right), squeeze hooked end together and tighten screw

1"

(25 mm)

3½"

(89 mm)

1.

Prepare your 3-wire cable for

direct connection

1.

Connect neutral ground wire and

neutral wire

D

B

C

Remove center terminal block screw. Remove neutral ground

wire (B) from external ground conductor screw (C). Connect

neutral ground wire (B) and the neutral wire (D) (white or center

wire) of power supply cord/cable under center, terminal block

screw. Tighten screw.

Connect other wires

2.

Connect the other wires to outer terminal block screws.

Tighten screws.

3. Tighten strain relief screws.
4. Connect a separate copper ground wire from the external

ground conductor screw to an adequate ground.

5. Insert tab of terminal block cover into slot of dryer rear

panel. Secure cover with hold-down screw.

Optional 3-Wire Connection

IMPORTANT: You must verify with a qualified electrician that

this grounding method is acceptable before connecting.

Place the hooked ends of the other power supply cable wires

under the outer terminal block screws (hooks facing right).

Squeeze hooked ends together. Tighten screws.

3.

Connect other wires

4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear

panel. Secure cover with hold-down screw.

6. You have completed your electrical connection. Now go