beautypg.com

Warning, Starting and shutting down your furnace – Bryant 350AAV User Manual

Page 5

background image

5

Examine the furnace installation
monthly to determine that:
1. All flue gas carrying areas external

to the furnace (i.e. chimney, vent
connector) are clear and free of
obstructions.

2. The vent connector is in place,

slopes upward and is physically
sound without holes or excessive
corrosion.

3. The return-air duct connection(s)

is physically sound, is sealed to the
furnace casing, and terminates
outside the space containing the
furnace.

4. The physical support of the furnace

is sound without sagging cracks,
gaps, etc. around the base.

5. There are no obvious signs of dete-

rioration of the furnace.

6. The burner flames are in good

adjustment. (See Fig. 8.)

8

WARNING

FIRE AND UNIT OPERATION
HAZARD
Failure to follow this warning
could result in fire, personal in-
jury/death or property damage.
For proper and safe operation
the furnace needs air for com-
bustion and ventilation. Do not
block or obstruct the openings
on the furnace, air openings to
the area in which the furnace is
installed, and the space
around the furnace.

!

STARTING AND
SHUTTING DOWN
YOUR FURNACE

Instead of a continuously burning pilot
flame which wastes valuable energy,
your furnace uses an automatic, hot
surface ignition system to light the
burners each time the thermostat
starts your furnace.

9

Follow these important safeguards:

• Never attempt to manually light the
burners with a match or other source of
flame.
• Read and follow the operating
instructions on inside of main furnace
door, especially the item that reads as
follows:

Wait 5 minutes to clear out any gas.
Then smell for gas, including near
the floor. If you smell gas,

STOP!

Follow “B” in the safety information
above on this furnace label. If you
don’t smell gas, go to the next step.

• If a suspected malfunction occurs
with your gas control system, such as
the burners not lighting when they
should, refer to the shutdown proce-
dures on inside of main furnace door,
or in the “Shutting Down Your Fur-
nace” section and call your dealer as
soon as possible.

CHECK AIR FILTER:

Before

attempting to start your furnace, be
sure the furnace air filter is clean and
in place. See “Performing Routine

WARNING

FIRE HAZARD
Failure to follow this warning
could result in a fire or explo-
sion, and personal injury/
death or property damage.
Should the gas supply fail to
shut off or if overheating oc-
curs, turn off the external
manual gas valve to the fur-
nace BEFORE turning off the
electrical supply. (See Fig. 11.)

!

Maintenance” section in this manual.
Then proceed as follows:

STEPS FOR STARTING
YOUR FURNACE

1. Set your room thermostat to the

lowest temperature setting.
(See Fig. 10.)

a

10

11

12

2. Close the external manual gas

valve. (See Fig. 11.)

3. Turn OFF electrical supply to the

furnace. (See Fig. 12.)

4. Remove main furnace door. (See

Fig. 13.)

5. The gas valve will have a control

switch to turn OFF or ON. Turn
control switch on the gas control to
the OFF position and wait 5 min-
utes. (See Fig. 14 or 15.) Then
smell for gas, including near the

®

CL

O

S

E

This manual is related to the following products: