75.1038 V3 Jun 2005 [Rev. June 10, 2005]

Page 6 of 8


PROGRAMMING
GUIDE Cont.
UNLOCKING &
LOCKING
















































`




























Sensitivity alters the sensitivity of the
motion field. Values range from 0 to 9,
minimum to maximum respectively.

LOCK

UNLOCK

0-9

0-9

0-9

0-9

Press the UNLOCK key once, then enter
your 4-digit code to unlock the Eagle.

0000

The red LED will flash quickly after
UNLOCK is pressed once. After
entering the valid code, Eagle will
flash red LED slowly.

If access code is set to the factory
default value of 0000, the Eagle will
automatically unlock after the
UNLOCK key is pressed once. The
red LED will immediately begin to
slowly flash red.

When all parameters have been set, press
the LOCK key once. If you wish to enter a
new access code, use the 0-9 number keys
and enter the new 4-digit code within 10
seconds. The code must begin with the
number 1.
If you choose not to enter a new code,
press the LOCK key once more, and the
existing code will be retained.

0000

After locking, the red LED stops
flashing and the sensor will no longer
be in a program mode.

= Locked with existing code.

0-9

0-9

0-9

0-9

= Locked with new code that is entered.

KEY USER’S ACTIONS DEFAULT LED STATUS

Press the function key that you desire to
inquire about, followed by pressing the
CHECK VALUES key.
After pressing INQUIRY, count the number
of LED flashes – this corresponds to the
setting.

EXAMPLE:

After pressing a function button, the
red LED flashes quickly. After pressing
the CHECK VALUES key, the LED
flashes the number of the current
setting. No LED flash will indicate a
setting of 0.

7 = Default sensitivity
value

CHECK VALUES

SENSITIVITY


0 = Minimum sensitivity
9 = Maximum sensitivity

7

After pressing the SENSITIVITY key,
the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.

RELAY HOLD TIME

Relay hold time refers to the hold time on
the output relay of the Eagle. Values range
from 0 to 9, .5 seconds to 9 seconds
respectively.

0

After pressing the RELAY HOLD TIME
key, the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.

0 = .5 secs.

1 = 1 sec. to 9 = 9 seconds. 1
through 9 in 1 second increments.

RELAY

CONFIGURATION

After pressing the RELAY
CONFIGURATION key, the red LED
flashes quickly. After pressing a
number button, the red LED flashes
slowly. (Normally Open relay indicates
relay closes upon detection, and is
open upon a power loss).

1

The relay configuration has 4 possible
output values:

1 = Normally open relay
2 = Normally closed relay
3 = Continuous detection
4 = Continuous non-detection