PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi (138

and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7 milliliters) per

second. A shut off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure

is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The regulator is also necessary if the water source has

pressure fluxuations. The main water inlet is a 3/8” (9.52 mm) MFL connection.

NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene,

before the dispenser will facilitate movement to clean the countertop. It can be purchased direct from BUNN-O-MATIC (part

number 34325.10_ _ [see Illustrated Parts Catalog for complete part number.]) BUNN-O-MATIC does not recommend the

use of saddle valves to install the dispenser. The size and shape of the hole(s) made in the supply line(s) by saddle valves

may restrict water flow.

This

equipment must be installed to comply with the International Plumbing Code of the International

Code Council and the Food Code Manual of the Food and Drug Administration (FDA). For models installed

outside the U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area.

INITIAL SET-UP

CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move the

dispenser. Place dispenser on a sturdy counter or shelf able to support at least 150 lbs. (68 kg). This dispenser is designed

for indoor use only.

Set the dispenser on the counter where it will be used. This dispenser requires a minimum of 4 inches (102 mm) of air

clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is required between

the dispenser sides and the wall or another appliance. For optimum performance, do not let warm air from surrounding

machines blow on the dispenser. Leave some space so the dispenser can be moved for cleaning.

ELECTRICAL REQUIREMENTS

CAUTION: The dispenser must be disconnected from the power source until specified in Electrical Hook-Up.

The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit rated

120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R.

The 230V rated dispenser has an attached cord set and requires an attachment plug cap rated at least 230 volts ac, 15

amp. The attachment plug cap must meet with applicable national/local electrical codes.

Refer to the data plate for exact electrical requirements.

ELECTRICAL HOOK-UP

CAUTION: Improper electrical installation will damage electronic components.

1. An electrician must provide electrical service as specified.

2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.

3. Confirm that the refrigeration switch on the rear of the dispenser is in the OFF position.

4. Connect the dispenser to the power source.

5. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing has

been hooked up, the dispenser is ready for Initial Fill.

39992 011210

CE REQUIREMENTS

• This appliance must be installed in locations where it can be overseen by trained personnel.

• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.

• Appliance shall not be tilted more than 10° for safe operation.

• An electrician must provide electrical service as specified in conformance with all local and national codes.

• This appliance must not be cleaned by water jet.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili-

ties, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by

a person responsible for its safety.

• Children should be supervised to ensure they do not play with the appliance.

If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special

cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.

• Machine must not be immersed for cleaning.