GUIDE SPECIFICATIONS

Gas Furnace

310AAV/JAV

General

SYSTEM DESCRIPTION

Furnish a _________________ fixed capacity gas-fired

furnace for use with natural gas or propane (factory

authorized conversion kit required for propane); furnish

cold air return plenum.

QUALITY ASSURANCE

Unit will be designed, tested and constructed to the

current ANSI Z 21.47/CSA 2.3 design standard for

gas-fired central furnaces.

Unit will be 3rd party certified by CSA to the current

ANSI Z 21.47/CSA 2.3 design standard for gas-fired

central furnaces.

Unit will carry the CSA Blue StarR label.

Unit efficiency testing will be performed per the current

DOE test procedure as listed in the Federal Register.

Unit will be certified for capacity and efficiency and

listed in the latest AHRI Consumer’s Directory of

Certified Efficiency Ratings.

Unit shall carry the current Federal Trade Commission

Energy Guide efficiency label.

DELIVERY, STORAGE AND HANDLING

Unit shall be shipped as single package only and is

stored

and

handled

per

unit

manufacturer’s

recommendations.

WARRANTY (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available

upon request.

Products

EQUIPMENT

Components shall include: slow-opening gas valve to

reduce ignition noise, regulate gas flow, with electric

switch gas shut-off; flame proving sensor, hot surface

igniter, pressure switch assembly, flame rollout switch,

blower and inducer assembly, 40va transformer;

low--voltage (heating) (heating/cooling) thermostat.

Blower Wheel and Blower Motor

Galvanized blower wheel shall be centrifugal type,

statically and dynamically balanced. Blower motor of PSC

type shall be permanently lubricated with sealed bearings,

of _______hp, and shall be multiple-speed direct drive.

Blower motor shall be soft mounted to the blower scroll to

reduce vibration transmission.

Filters

Furnace may have reusable-type filters. Filter shall be

_______ in (x) _______in. (mm).

Casing

Casing shall be of .030 in. (.76 mm) thickness

minimum, pre--painted galvanized steel.

Inducer Motor

Inducer motor shall be soft mounted to reduce vibration

transmission.

Draft Safeguard Switch

Draft Safeguard Switch (blocked vent safeguard) shall

be factory installed to reduce the possibility of vent gas

infiltration due to a blocked or restricted vent pipe.

Heat Exchangers

Heat exchangers shall be a 4-Pass 20 gage aluminized

steel of fold-and-crimp sectional design when applied

operating under negative pressure.

Controls

Control shall include a micro-processor non--volatile

memory based integrated electronic control board with at

least 11 service troubleshooting codes displayed via

enhanced flashing LED diagnostic light on the control, a

self-test feature that checks all major functions of the

furnace

within

one

minute,

and

a

replaceable

automotive-type

circuit

protection

fuse.

Multiple

operational settings available including, separate blower

speeds for heating, cooling, and continuous fan.

Continuous fan speed may be adjusted from the

thermostat. Cooling airflow will be selectable between 350

or 400 CFM per ton of air conditioning.

OPERATING CHARACTERISTICS

Heating Capacity shall be ________ Btuh input;

________ Btuh output capacity.

Fuel Gas Efficiency shall be 80% AFUE.

Air delivery shall be ___________ CFM minimum at

0.50 In. W.C. external static pressure.

Dimensions shall be: depth __________ in. (mm);

width _________ in. (mm); height_________in. (mm)

(casing only). Height shall be_________in. (mm) with

A/C coil and _____________in. (mm) overall with

plenum.

ELECTRICAL REQUIREMENTS

Electrical supply shall be 115 volts, 60 Hz,

single--phase (nominal). Minimum wire size shall

be_________AWG; maximum fuse size or circuit breaker

shall be __________Amps.

SPECIAL FEATURES

Refer to section of the product data sheet identifying

accessories and descriptions for specific features and

available enhancements.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

E

2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 09/10

Replaces: PDS 310A.45.5

Catalog No. PDS310A.45.6

310AA

V

/J

A

V