Exhaust air connection

d

WARNING

d

1. To reduce the risk of fire, this

dryer MUST BE EXHAUSTED

OUTDOORS.

2. To reduce the risk of fire, do

not use ducting longer than

recommended.

3. To reduce the risk of fire, only

use rigid or flexible metal duct.

4. DO NOT use a duct smaller

than 4 inches in diameter.

5. DO NOT use exhaust hoods

with magnetic latches.

6. DO NOT exhaust the dryer into

a chimney, furnace cold air

duct, attic, crawl space, or any

other ductwork used for

venting.

7. DO NOT install a flexible duct

in an enclosed wall, ceiling or

floor.

8. DO NOT crush or kink the

duct.

9. Do clean and inspect the

exhaust system on a regular

basis; at least once a year.

10. The exhaust duct must

terminate in a manner to

prevent back drafts or entry

of animals.

To prevent buildĆup of moisture and

accumulation of lint indoors, as well

as to maintain maximum drying

efficiency, this dryer must be

exhausted outdoors.

i

Position the exhaust air duct so

that there is no counterĆ

pressure (e.g. from wind) on the

exhaust outlet.

There are exhaust air outlets in the

rear panel of the dryer (1) and in the

left side wall (2).

Select the most suitable exhaust air

outlet after installing the dryer.
Change the exhaust tube to the

suitable position and cover the

other outlet with the fascia cover -

turn it in a clockwise direction.

Place the end of the exhaust air

duct in the air outlet without

bending the duct. Use duct clamp

to secure the air duct. The exhaust

air duct should only be positioned

horizontally or vertically and never

left to sag.

Ductwork
To ensure optimum performance,

the ducting system of the dryer

should be as short as possible with

a minimum number of elbows.

Your dryer will work best when the

venting system has as few air flow

restrictions as possible. Exhaust

ducting which is longer than

recommended may extend drying

time, cause lint to accumulate and

affect dryer performance and dryer

lifeĆtime.
Whether connecting to an existing

venting system or a new venting

system, make sure that all ducting

is clean and free of lint.
The maximum permitted length for

both rigid and flexible metal duct is

shown in the tables below.

11.

Exhaust air outlet in the rear panel

of the dryer:

Number of

90° Turns

or Elbows

Rigid Duct

Flexible Duct

0

30 ft.

(914 cm)

20 ft.

(610 cm)

1

22 ft.

(671 cm)

15 ft.

(457 cm)

2

14 ft.

(427 cm)

9 ft.

(274 cm)

3

6 ft.

(183 cm)

4 ft.

(122 cm)

Exhaust air outlet in the left side

wall of the dryer:

Number of

90° Turns

or Elbows

Rigid Duct

Flexible Duct

0

22 ft.

(671 cm)

15 ft.

(457 cm)

1

14 ft.

(427 cm)

9 ft.

(274 cm)

2

6 ft.

(183 cm)

4 ft.

(122 cm)