beautypg.com

Water treatment – Bosch 25/32kW User Manual

Page 36

background image

WATER TREATMENT

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32

8 716 113 389b (09/07)

35

C

O

MMI

S

S

IO

N

IN

G

WATER TREATMENT

IMPORTANT: Debris from the system can
damage the boiler and reduce efficiency.
Failure to comply with the guidelines for the
use of water treatment with the appliance
will invalidate the appliance warranty.

FLUSHING (Central Heating):
1

Switch off the boiler.

Open vented systems only: turn off the

water to the system header tank.

Open all radiator valves/drain cocks (C) and

drain the system while the appliance is hot.

Close drain cocks (C).

2

Add a suitable flushing agent (F) and refill

the system at the correct strength for the
system condition in accordance with the
manufacturer's instructions.

Vent the boiler (there are two vent points

(A) at the top of the secondary heat

exchanger. Only one may be in use, the
other may be obscured by side fluing.
Always vent (A) and the vent screw (B) on
the pump and all radiators.

Run the boiler/system at normal operating

temperature for the time stated by the
flushing agent manufacturer.

3

Drain and thoroughly flush the system and

boiler to remove the flushing agent and
debris (C).

INHIBITOR (Central Heating):
4

Check drain cocks (C) and manual air vents

are closed and all radiator valves are open.

5

Add a suitable inhibitor (I), (or combined

inhibitor/anti-freeze if the system is exposed
to freezing conditions) to the heating system
in accordance with the manufacturers
instructions.

The inhibitor or combined inhibitor/anti-freeze
must not cause damage to the materials within
the boiler (mild steel, stainless steel, copper
and brass) and any other materials/components
within the system.

Open vented systems only: turn on the

water to the system header tank and allow
the system to fill.

Sealed systems only: fill the system to

between 1 and 2 bar via a WRAS approved
filling loop. Check the system pressure
during venting and repressurise if
necessary.

6

Vent the boiler (there are two vent points

(A) at the top of the secondary heat

exchanger. Only one may be in use, the
other maybe obscured by side fluing.
Always vent (A) and the vent screw (B) on
the pump and all radiators; retighten vents
when complete.

7

Record the date when the inhibitor was

added to the system on the guarantee card.

NOTE: The concentration level of inhibitor

in the system should be checked every 12
months or sooner if system content is lost.

The addition of sealing agents to the system
water is not advised as this can cause
problems with deposits left in the heat
exchanger and invalidate the appliance and
heat exchanger warranty .

2

1

3

4

5

6

1 - 2 bar

A

A

B

B

C

C

C

C

C

This manual is related to the following products: