INSTALLATION NOTES:

Ensure all the seals are in good condition
and seated properly.
To ease assembly of flue components,
grease seals lightly with the solvent free
grease supplied.
A terminal guard must be fitted if the
terminal is 2m or less above a surface where
people have access.

All flue options:
1

Lightly grease the flue cowl seal with the

solvent free grease supplied.

2

Carefully remove the blanking plate from

the appropriate flue aperture (if necessary)

and refit the blanking plate in the unused

aperture.

3

Carefully remove the insulation from the

flue aperture in the cabinet that the flue is
to pass through, and fit to the unused
aperture (if necessary).

4

Refer to the flue manual supplied with the

flue kit for flue installation.

FLUE INSTALLATION

FLUE INSTALLATION

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32

8 716 113 389b (09/07)