Flue installation – Bosch 25/32kW User Manual
Page 22
INSTALLATION NOTES:
Ensure all the seals are in good condition
and seated properly.
To ease assembly of flue components,
grease seals lightly with the solvent free
grease supplied.
A terminal guard must be fitted if the
terminal is 2m or less above a surface where
people have access.
All flue options:
1
Lightly grease the flue cowl seal with the
solvent free grease supplied.
2
Carefully remove the blanking plate from
the appropriate flue aperture (if necessary)
and refit the blanking plate in the unused
aperture.
3
Carefully remove the insulation from the
flue aperture in the cabinet that the flue is
to pass through, and fit to the unused
aperture (if necessary).
4
Refer to the flue manual supplied with the
flue kit for flue installation.
FLUE INSTALLATION
FLUE INSTALLATION
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32
8 716 113 389b (09/07)
21
IN
ST
AL
LA
TI
O
N