beautypg.com

2 specifications (technical data) – Bosch GWH 2700 ES LP User Manual

Page 5

background image

6 720 608 542

Appliance details

5

2.2

Specifications (Technical data)

Approved in US/Canada

Capacity

Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.

Maximum output

160,500 Btu/h (47.0 kW)

Maximum input

199,000 Btu/h (58.3 kW)

Efficiency in %

Thermal efficiency > 82%

Min. Input

19,900 Btu/h (5.8 kW)

Temperature Control

Selection range: 100°F (38°C) - 140°F (60°C)

Default temperature: 122°F (50°C)

Stability: +/- 2°F (+/- 1°C)

Gas Requirement

Gas connection (inches) - ¾”

Inlet gas pressure under operation (with a high hot
water flow rate)*

• Propane: 8” - 13” water column

• Natural Gas: 3.5” - 10.5” water column.

* To measure gas pressure, see Measuring Gas
Pressure, chapter 3.12.

Water

• Hot water connection (inches) - ¾”

• Cold water connection (inches) - ¾”

• Water valve material: Polymer (PPS) (Polypropylene

Sulfid)

• Minimum water flow: 0.65 gallon/minute (2,5 l/m).

Note: Activation varies with inlet water temperatures
from 0.65 - 1.6 gallon/minute.

• Minimum recommended water pressure: 30 PSI

(2.07 bar)

• Minimum recommended well pressure: 40 PSI (2.75

bar), see chapter 3.9.

• Connections:

– Bottom of heater

Combustion

• NOx ≤ 40 Ng/J

(Nanograms of NOx (calculated as NO2) per

Joule of heat output).

• CO ≤ 250 ppm (measured)
• CO

2

level set from factory, see chapter 6.4.

Dimensions

• Depth (in): 11¼” (286 mm)

• Width (in): 17

7

/

8

” (452 mm)

• Height (in): 30½” (775 mm)

• Weight: 67 pounds (30,5 kg).

Gas types

Natural Gas.
LP Gas.
Converting the gas type can only be done by a certified
gas technician with a calibrated CO

2

analyzer.

Call

Bosch

Water

Heating

through

Bosch

thermotechnology corp.

for conversion instructions.

Voltage

120 V AC (60 Hz) nominal

Amperage

Idle - 40 mA
Operation -

≤ 2.5 A

Noise

45 - 65 db (A)

Safety devices

• Flame failure device (ionization flame rod sensor)

• Pressure relief valve (supplied with heater)

• Over heat prevention (temperature limiter)

• Inlet temperature sensor

• Outlet temperature sensor

• Backflow temperature sensor.

Water protection

IP X4 (protection against water drops)

i

If appliance is installed at elevations above
2000ft, refer to section 3.3.6 Fan speed
adjustment.