5 program values – Bosch GWH 2700 ES LP User Manual
Page 36
6 720 608 542
36
Maintenance and service
6.5
Program values
This section describes details on programming the
appliance. For most applications the factory default
values will robust and stable operation. Only adjust the
factory settings if the installation requires changes as
indicated in the appropriate section of this manual.
Refer to chapter 6.6 Control board diagnostics (page
37) regarding how to access these P-modes.
Caution:
Misadjusted
program
values can lead to appliance
malfunction, errors, and service
calls.
Program
Description
Factory Default
MIN
MAX
Comment
P1
Maximum Power
NG: 48, LP: 46
21
NG: 50, LP: 49
see chapter 3.12, page 27.
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
P2
Minimum Power
7
7
20
see chapter 3.3.6, page 17
P3
Remote Con-
trols installed
_0
_0
6
see chapter 5.5, page 31
P4
Access to Diag-
nostic Mode
E
0d
10f
see chapter 6.6, page 37
P5
Cascade Mode
NO
NO
CC
contact Bosch for details
P6
Temperature
Unit
°F
°F
°C
P7
Appliance Type
NO
Cd
NO
Condensing / Non-condensing*
P8
Back light
dE
dE
ON
dE turns back light off after 60
seconds
from
last
button
pushed, ON turns backlight on
permanently
P9
Fan Purge
runs secondary and primary fan
when P9 is selected by
depressing the “P” - button
Table 18 Program values, factory default settings and ranges.
* Incorrect setting causes errors.