Installation instructions

17

3.3.6

Fan speed adjustment

IMPORTANT! Installation adjustment:

After installing the water heater, the fan speed values for
minimum power (P2) and maximum power (P1) may
need adjustment due to variations in altitude and vent
pipe length.
Failure to make necessary adjustments to fan speed
values may result in improper operation of the
appliance.

First calculate the total equivalent vent length. Use this
value to determine the appropriate fan speed values,
found in Table 12 and make any necessary
adjustments. After changing fan speed values proceed
to Section 6.4 to confirm CO

2

values are within

specified ranges.

Total equivalent vent length calculation

B

Determine the total length of all straight sections of
vent pipe and enter in table 10, line 1.

B

Count the number of 90° elbows used and enter that
value in line 2. (Do not count terminals and first elbow
used on intake and exhaust).

B

Count the number of 45° elbows used and enter that
value in line 3.

B

Repeat steps 1 through 3 for air intake pipe and enter
those values in the intake section of table 10.

B

Add line 4 from Exhaust to line 4 of Intake and enter
result in line 5.
This is the total equivalent vent length.

Example

Exhaust

• 7 - 3' straight sections

• 1 - 1' straight section = Total straight pipe length 22’

• 2 - 90° elbow.

Intake

• 5 - 3' straight sections = Total straight pipe length 15’

• 1 - 90° elbows.

Example

Note:

Do not count terminals and first elbow used on

intake and exhaust.

Exhaust

1

Straight section length
(feet)

__ x 1 =

____

2

90° elbows (qty)

__ x 2.5 =

____

3

45° elbows (qty)

__ x 1.25 =

____

4

Total:

____

Intake

1

Straight section length

__ x 1 =

____

2

90° elbows (qty)

__ x 2.5 =

____

3

45° elbows (qty)

__ x 1.25 =

____

4

Total:

____

5

Total equivalent vent length =

____

Table 10 Determining vent length combination (see

example in Table 11)

Exhaust

Straight section length
(feet)

22 x 1 =

22

90° elbows (qty)

1 x 2.5 =

2.5

45° elbows (qty)

0 x 1.25 =

0

Total:

24.5

Intake

Straight section length
(feet)

15 x 1 =

15

90° elbows (qty)

1 x 2.5 =

0

45° elbows (qty)

0 x 1.25 =

0

Total:

15

Total equivalent vent length =

39.5

Table 11 Determining vent length combination exam-

ple

i

Total equivalent length must not to
exceed 57ft.

i

NOTE: If using concentric terminal include
exhaust pipe length that is part of the con-
centric terminal.