6 720 608 542

Installation instructions

15

Fig. 17 Vertical venting installation (twin pipe penetra-

tion)

Fig. 18 Vertical venting installation - Masonry Chim-

ney (combustion air piping not shown)

3.3.4

Vent connections

B

Attach the flue gas exhaust accessory (8 705 504
162) to the top of the unit (position 1) using the 4
screws and gasket provided. Fully insert stainless
steel vent pipe 1.5” minimum into the accessory and
tighten the clamp (position 2).

Fig. 19

B

Attach the combustion air inlet accessory (8 705
504 116) to the top of the unit (position 3) using the
3 screws and gasket provided, and install air intake
pipe over the accessory. NOTE: The appliance has
the option to mount the combustion air inlet acces-
sory on the top right or on the top left side of the
heater. The combustion air inlet that is not used must
be kept sealed.

Fig. 20

B

Ensure that exhaust vent pipe is fully inserted in collar
to enable proper connection.

CHIMNEY

MORTAR

HANGER STRAP

HORIZONTAL RUN
1/4" RISE/FT

ELBOW

APPLIANCE

MAY BE INSULATED
IF NECESSARY

6720608158-14.2AL

HOSE
CLAMP

ELBOW

RAIN CAP

STORM COLLAR

SILICONE SEAL

FLASHING

CONDENSATE

DRAIN

2' MIN.

10' MIN.

3' MIN.

i

NOTE: Vent pipe must be completely ver-
tical when inserting or gasket inside ex-
haust accessory can become displaced.
Exhaust accessory can be removed with
vent pipe attached to check gasket posi-
tion.

i

Exhaust venting must be 3" or 4" sealed
single wall stainless steel (AL29-4C) vent
pipe.