Installation instructions

Adjusting minimum power fan speed (P2)

To select fan speed:

B

Press ON/OFF button into OFF.

B

Press and hold "Program" button

and press

ON/OFF button to turn appliance ON.

Fig. 22

B

As soon as '188' is displayed, release "Program"
button

, and the display should read P2.

B

Press

or

to choose the fan speed suitable

with your installation, see Table 12.

B

Press and hold (± 5 sec.) “Program” button

until

the display flashes, then the selected value is memo-
rized.

Adjusting maximum power fan speed (P1)

To select fan speed:

B

Press ON/OFF button into OFF.

B

Press and hold "Program" button

and press

ON/OFF button to turn appliance ON.

Fig. 23

B

As soon as '188' is displayed, release "Program" but-
ton

, and the display reads P2.

B

Press the minus button

to display P1.

B

Press “Program” button

to enter P1 adjustment.

The current setting will appear on the display.

B

Press

or

to choose the fan speed suitable

with your installation, see Table 12.

B

Press and hold (± 5 sec.) “Program” button

until

the display flashes, then the selected value is memo-
rized.

Natural Gas

Liquid propane

Altitude

(above sea

level)

Total

equivalent

vent length

1)

Minimum

power fan

speed (P2)

Maximum

power fan speed

(P1)

Maximum

power fan speed

(P1)

0 - 2000 ft

(0 - 610 m)

5.5 - 32 ft

7

No

modification required

No

modification required

For operation at elevations

above 2,000 ft (610 m) the

equipment ratings shall be

reduced at the rate of 4% for

each 1,000 ft (305 m) above sea

level

33 - 57 ft

8

2000 - 4500 ft

(610 - 1372 m)

5.5 - 32 ft

8*

48*

47*

33 - 57 ft

8*

49*

48*

4500 - 8000 ft

(1372 - 2439 m)

5.5 - 32 ft

9*

49*

48*

33 - 57 ft

9*

50*

49*

* Above 2000 ft, CO

2

levels must be checked with a combustion gas analyzer, see section

6.4

for instructions.

Table 12 Fan speed adjustment

1)

Full equivalent length (inlet + outlet piping + fittings)

i

Do not set P2 to greater then 9.

i

Proceed directly to Section 6.4 to confirm
CO

2

values are within range.