beautypg.com

26f t, Min. 3 feet 3” stainless steel pipe – Bosch GWH 2700 ES LP User Manual

Page 14

background image

6 720 608 542

14

Installation instructions

3.3.3

Venting configuration examples

Below are approved examples of horizontal
venting installations.

Fig. 13 Horizontal side wall venting installation (single

pipe penetration)*

* Warning: for non-freezing climates only!

Important:
Note: Pitch horizontal runs down toward the heater,
except horizontal run between last elbow and termina-
tion which must slope down to termination 1/4" per
foot.

Note: For horizontal terminations, venting must
terminate once it penetrates to the outside of the
structure. There must be no sections of vent pipe
exposed to the outdoors.

Fig. 14 Horizontal venting installation (concentric

penetration)

Fig. 15 Horizontal twin pipe penetration

Below are approved examples of vertical venting
installations.

Important:

Note: Pitch horizontal runs down toward the heater,
1/4" per foot.

Fig. 16 Vertical venting installation (single pipe pene-

tration)*

* Warning: for non-freezing climates only!

4"

6720608542-02.2AL

HORIZONTAL RUN

1/4" PER FOOT

DOWN TO

TERMINATOR.

CONDENSATE

DRAIN

12"

6720608782-11.1Av

Min. 3 Feet

3” stainless steel pipe

6720608542-05.2AL

26f

t

FIRESTOP SUPPORT

ELBOW

APPLIANCE

HOSE
CLAMP

RAIN CAP

STORM COLLAR

FLASHING

FIRESTOP SUPPORT

4" MIN.

AIR SPACE

6720608158-91.2Av

CONDENSATE

DRAIN

2' MIN.

10' MIN.

3' MIN.

This manual is related to the following products: