An identification tag is permanently mounted on
the cabinet.
Permanent wiring or electrical outlets for this
appliance must be installed by a licensed electrician
in accordance with local, country, or national codes.
This appliance must be connected to a dedicated
circuit: (see below)
HSM-38/3S –– 20 Amp circuit
HSM-48/5S –– 30 Amp circuit
Always position the appliance so the power supply
cord is easily accessible in case of emergency. Plug
the unit into a properly grounded receptacle ONLY.
Arcing will occur when connecting or disconnecting
the unit unless all controls are in the OFF position.
I N S T A L L A T I O N
E L E C T R I C A L
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
ELECTRICAL, HSM-38/3S
THREE SHELF UNIT
voltage
phase
cycle
/
hz
amps
kW
cord
,
no
plug
208-240
(aGcY)
1
60
10
5.7
NeMa
6-20P
at 208
1
60
10.8 2.3
20A-250V
at 240
1
60
12.5 3.0
recommended
must
be
on
it
’
s
own
20
amp
circuit
230
1
50
11.8 2.7
cord
,
no
pluG
ELECTRICAL, HSM-48/5S
FIVE SHELF UNIT
voltage
phase
cycle
/
hz
amps
kW
cord
,
no
plug
208-240
(aGcY)
1
60
24
5.7
NeMa
L6-30P
at 208
1
60
20.6 4.3
30A-250V
at 240
1
60
24
5.7
recommended
must
be
on
its
own
30
amp
circuit
380-415
1
50
10
5.7
cord
,
no
pluG
Wire diagrams are included in the literature
package supplied with the unit.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
NOTE
:
CE approved appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.