inStallation

/

operation

/

Service

Manual

An identification tag is permanently mounted on

the cabinet.
Permanent wiring or electrical outlets for this

appliance must be installed by a licensed electrician

in accordance with local, country, or national codes.
This appliance must be connected to a dedicated

circuit: (see below)

HSM-38/3S –– 20 Amp circuit

HSM-48/5S –– 30 Amp circuit

Always position the appliance so the power supply

cord is easily accessible in case of emergency. Plug

the unit into a properly grounded receptacle ONLY.

Arcing will occur when connecting or disconnecting

the unit unless all controls are in the OFF position.

I N S T A L L A T I O N

E L E C T R I C A L

D A N G E R

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

ELECTRICAL, HSM-38/3S

THREE SHELF UNIT

voltage

phase

cycle

/

hz

amps

kW

cord

,

no

plug

208-240

(aGcY)

1

60

10

5.7

NeMa

6-20P

at 208

1

60

10.8 2.3

20A-250V

at 240

1

60

12.5 3.0

recommended

must

be

on

it

s

own

20

amp

circuit

230

1

50

11.8 2.7

cord

,

no

pluG

ELECTRICAL, HSM-48/5S

FIVE SHELF UNIT

voltage

phase

cycle

/

hz

amps

kW

cord

,

no

plug

208-240

(aGcY)

1

60

24

5.7

NeMa

L6-30P

at 208

1

60

20.6 4.3

30A-250V

at 240

1

60

24

5.7

recommended

must

be

on

its

own

30

amp

circuit

380-415

1

50

10

5.7

cord

,

no

pluG

Wire diagrams are included in the literature

package supplied with the unit.

Hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

NOTE

:

CE approved appliances must be

connected to an electrical circuit that is

protected by an external GFCI outlet.

For CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.