beautypg.com

Charging mode and time, Safety functions – AEG Micro-Processor Charging Unit LP 3.8 User Manual

Page 20

background image

20

Protection Description
overheat

the charger is protected by NtC

(negative temperature coefficient)

control to protect itself from damage.
During the charging process, if the

charger becomes too hot or due to

high ambient temperature, the power

output is automatically reduced.
the charger continues to trickle

charge and automatically starts

increasing power when the

temperature drops.

mCU

Control

Fully controlled by internal

micro-Computer-Unit (mCU), which

assures a faster, powerful, reliable

and smarter charging process.
plugged in, the charger

detects the state of charge of the

battery.

initiates charging process.

spark

to eliminate the possibility of sparks,

the charger will not begin operation

upon connection to the battery, unless

charging mode has been selected.

Housing protection dust and splash

proof (ip65) double insulated

CHargiNg moDE

aND timE

Battery

size (Ah)

Mode

For about

80% charge

(hours)

2

small batteries

< 14.4 a

2

8

8

20

large batteries,

normal

conditions

large batteries,

temperatures

below 0 °C

4.5

60

14

100

23

120

28

saFEtY FUNCtioNs

the charge is protected from user error and pre-

vents damage to the connected battery.

No risk of overcharging!

the charger will not damage the electronics in your

vehicle.

Protection Description
abnormal

operation

to avoid damage to charger and

battery, the charger will turn off its

own electronic system and will im-

mediately reset the system to basic

settings in the case of

short circuit

wrong connection

open circuit

reversed polarity connection

battery voltage below

8.0 V ± 0.5 V

the charger will remain in staNDBY

mode and FaULt LED is lit to indicate

reverse polarity or fault.