Indications / charging modes – AEG Micro-Processor Charging Unit LP 3.8 User Manual
Page 17

17
GB
iNDiCatioNs /
CHargiNg moDEs
9 10 11
12
13
14
15
16
9
Charging mode 14.4 V / 0.8 a max
suitable for charging
small batteries < 14 ah
10
Charging mode 14.4 V / 3.8 a max
suitable for charging large batteries in
normal conditions (normally used for
WEt, mF and most gEL batteries).
11
Charging mode 14.7 V / 3.8 a max
suitable for charging large batteries
in sub-zero temperatures and several
agm batteries with capacity of more
than 14 ah.
12
Fault!
incorrect polarity
13
Fully charged
14
Charging in progress
15
Before charging mode selection and
in case of open circuit, short circuit or
reverse connection.
16
„mode“ selection button
Technical data
maximum
charging
capacity
3800 ma
Charging
characteristic
5-level (iiUoiUp characteristic)
For battery types gel, agm, lead acid,
maintenance-free and
low-maintenance batteries
Battery voltage
12 V
operating volt-
age
230 V aC
recommended
for battery
capacity
1.2 - 120 ah
Display
LED (charging progress etc.)
safety features
overloading, short circuit,
overheating and voltage reversal
protection as well as anti-spark
and electronic-proof (no damage
of sensitive on-board electronics)
Fuse
the (+) pole connector cable (red) with a ring con-
nector is secured with a flat plug-in fuse (10 a). it is
activated in the case of short circuits or voltage peaks
and must be replaced subsequently.
Change fuse:
Attention! Do not install a stronger fuse. otherwise
the electronics could be damaged.
1. open the protective casing
2. remove the defective flat plug-in fuse
3. insert a new flat plug-in fuse of the same size (10 a)
into the slot
4. Close the protective casing once again