Charging phases – AEG Micro-Processor Charging Unit LW 60.0 User Manual
Page 33
GB
33
cHarGInG PHases
Step 1: Condition check
The charger checks the battery condition and calculates the required
charging parameters
Voltage
function
0 V to 05 V
„error“ leD (18) lights up Incorrect connection
05 V to 15 V
„Bad Battery“ leD (10) lights up Battery defective
15 V to 12 V
charging will start
12 V to 14 V
Trickle charge will start
14 V to 15 V
Battery fully charged „full“ leD (11) lights up
>15 V
„error“ leD (18) lights up
Step 2: Precharging
The battery is gently charged with a low charging current to return the battery to a
chargeable state
Step 3: Soft start
The battery is gently charged with a low charging current
Step 4: Full load charging
The battery is quickly and safely charged at the set charging current
Step 5: Absorptionsladung
The battery is charged at a current end-of-charge voltage until charging current
no longer flows
Step 6 Float charge
The charging voltage will be reduced, charging is complete
Step 7: Monitoring
The charger monitors the battery capacity once the battery falls below 128 V,
the charger will emit a charging pulse This maintains the battery’s highest possible
charging level