Agilent Technologies E3632A User Manual
Page 77

Chapter 4 Remote Interface Reference
SCPI Command Summary
74
APPLy {
current
>|DEF|MIN|MAX}]
APPLy?
[SOURce:]
CURRent[:LEVel][:IMMediate][:AMPLitude]{
|MIN|MAX|UP|DOWN}
CURRent[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX]
CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
{
CURRent[:LEVel][:IMMediate]:STEP[:INCRement]? {DEFault}
CURRent[:LEVel]:TRIGgered[:AMPLitude] {
CURRent[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX]
CURRent:PROTection[:LEVel] {
CURRent:PROTection[:LEVel]? {MIN|MAX}
CURRent:PROTection:STATe {0|1|OFF|ON}
CURRent:PROTection:STATe?
CURRent:PROTection:TRIPped?
CURRent:PROTection:CLEar
VOLTage[:LEVel][:IMMediate][:AMPLitude]{
VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX]
VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]
{
VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]? {DEFault}
VOLTage[:LEVel]:TRIGgered[:AMPLitude] {
VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX]
VOLTage:PROTection[:LEVel] {
VOLTage:PROTection[:LEVel]? {MIN|MAX}
VOLTage:PROTection:STATe {0|1|OFF|ON}
VOLTage:PROTection:STATe?
VOLTage:PROTection:TRIPped?
VOLTage:PROTection:CLEar
VOLTage:RANGe {P15V|P30V|LOW|HIGH}
VOLTage:RANGe?
MEASure
:CURRent[:DC]?
[:VOLTage][:DC]?
Output Setting and Measurement Commands