11

Operating Manual -

NE Multi Channel Power Amplifiers

4) Offset link group - Up to eight groups are available for the purpose of linking similar function parameters

across multiple channels. In addition to the control surface secondary level control (not the main fader), most

DSP functions have a link group check box in their work window to assign a specific parameter to one of the

eight link groups if desired. Link groups can be renamed by clicking on any group name and entering the new

name then pressing on the keyboard.

5) Attenuators - These two dials indicate the physical position of hardware controls on either the amp front panel

or the remote level control (if present). Note that these will display the position of attenuators even when

DISABLED in software.

6) Total Attenuation - This indicates the total amount of attenuation being applied to the channel. This is the sum

of the following attenuators: main fader, offset link group attenuation, front panel and remote attenuators (if

enabled).

7) Meters - Input and Output meters display the real time activity per channel, in dB below rated output. Also, the

amplifier’s operating temperature and output current are shown. Output current shows that the amplifier

channel is actually delivering output to a connected speaker load.

The Amplifier Control Surface