beautypg.com

4 canceling the operation prohibited state, Performing release setting – Konica Minolta bizhub 754 User Manual

Page 34

background image

bizhub 754/654

2-18

2.4

Canceling the Operation Prohibited State

2

2.4

Canceling the Operation Prohibited State

When access to the machine by the administrator of the machine through the Administrator Settings from the
control panel is authenticated, the machine enables the operation of Release Setting performed for canceling
the state of Prohibited Functions When Authentication Error (access lock state) as a result of unauthorized
access.

Release Setting clears the unauthorized access check count for all User Authentication, Account Track,
SNMP authentication, all Secure Print authentication, and all User Box authentication, resetting it to zero and
canceling the operation prohibited state. Perform the following procedure to cancel the operation prohibited
state.

Performing Release Setting

0

For the procedure to call the Prohibited Functions When Authentication Error screen on the display, see
steps 1 through 3 of page 2-16.

0

Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If
it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.

0

When the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after
turning it off. if there is no wait period between turning the main power switch off, then on again, the
machine may not function properly.
Here is the sequence, through which the main power switch and sub power key are turned on and off:
Turn off the sub power key ö Turn off the main power switch ö Turn on the main power switch ö Turn
on the sub power key

1

Call the Prohibited Functions When Authentication Error screen on the display from the control panel.

2

Touch [Release].

Operation Prohibited State

Canceling procedure

Administrator Settings

The Service Engineer touches [Administrator unlocking] to can-
cel the operation prohibited state.

The operation prohibited state is canceled after the main power
switch is turned off and on and the period of time set in [Re-
lease Time Settings] elapses.

User/Account authentication

The Administrator touches [Release] to cancel the operation pro-
hibited state.

Secure Print authentication

User Box authentication

SNMP authentication