4.4 TROUBLESHOOTING - AUTOFILL PUMP

PROBLEM

POSSIBLE CAUSE

REMEDY

Pump does not
operate.

1

Low water pressure.

1

Verify that there is adequate water pressure at
the inlet fi tting (30-50 psi).

2

Restriction or plugged auto fi ll system. 2

Flush and sanitize the pump and tubing.

3

Empty BIB

3

Replace BIB

Syrup
concentration
incorrect

1

BIB connector is not connected to the
BIB properly.

1

Check connection and reconnect if necessary.

2

Leak at the connections or in the
tubing.

2

Look for leaks at the connections and bubbles
in the tubing. Tighten clamps and replace
tubing if necessary.

3

Air in the BIB syrup container.

3

Remove the air from the BIB syrup container.

4

Pump is clogged with debris or
particulates.

4

Remove syrup valves and inspect for debris
or improper closing that would interfere with
operation.