Vollrath F144 User Manual
Page 20
Owner’s Manual #513677
14
F144I2, SF144I2 and SF121I2 Model Machines
4.4 EXTENDED
STORAGE
Refer to the following steps for storage of the machine
over any long period of shutdown time:
A.
Clean all the parts that come in contact with mix
thoroughly with a warm detergent water. Rinse
in clear water and dry all parts. Do not sanitize.
NOTE
Do not let cleaning solution stand in the freezing
cylinder or hopper during the shutdown period.
B.
Remove, disassemble, and clean the front door,
and auger shaft. Leave disassembled during the
shutdown period.
C.
Place the auger fl ights and auger support bushing
in a plastic bag with a moist paper towel. This will
prevent them from becoming brittle if exposed to
dry air over an extended period of time (over 30
days).
D.
For water-cooled machines that are left in unheated
buildings, or buildings subject to freezing, the water
must be shut off and disconnected. Disconnect
the water inlet fi tting. The fi tting is located at the
rear of the machine. Run the compressor for 2 - 3
minutes to open water valve (the front door must
be attached for the compressor to run). Blow
out all water through water inlet. Drain the water
supply line coming to the machine. Disconnect
the water outlet fi tting.
E.
Press the Main Power On/Off button to turn the
machine off.
F.
Disconnect the machine from the source of
electrical supply.