The discontinued touch panel control features and function are described below.

1

11

15

13

6

12

16

14

8

9

10

2

4

5

7

3

Figure 5. Discontinued Touch Panel Control
1. Electronic control panel.

2. Individual well Start/Stop switch. Push and hold to turn individual well on

and set heat level. Push again to turn well off.

3. Well indicator light. Lights when well is activated.

4. Well temperature display switch. Push and hold to display heat setting

selected for each individual well.

5. Master Start/Stop switch. Push to turn off all the wells at one time. Green

light indicates that the master switch may be used to reactivate all the

wells at the previous setting.

6. Heat setting display. Red lights indicate setting selected.

7. Clock. Used for time of day setting and Start/Stop programming.

8. Hour Set.

9. Minute Set.

10. Automatic Programming Start switch. Push to activate auto Start/Stop

Program. Clock must be set and operating to use this function.

11. Auto Start set switch.

12. Auto Stop set switch.

13. Preheat switch. Sets automatic 45 minute preheat when in automatic

mode. When used outside of automatic mode, pressing the automatic

preheat switch will give a 45 minute preheat at the high setting and then

revert to the selected temperature. Press for one second to engage.

14. Automatic heat switch. Used to set well heat setting when using auto

mode.

15. Auto start time display. Push to display start time preset.

16. Auto stop time display. Push to display stop time preset.

Control Panel Operation (Refer to Touch

Panel control diagram)

Start/Set Wells:

1. Push (2) and hold until desired heat setting (6) is displayed. (3) lights to

indicate well is on.

2. Push (4) to display heat setting for well.

3. Repeat for remaining wells.

Stop/Turn off Wells:

1. Push (2) to turn off well. (3) turns off to indicate well is off
OR
2. Push (5) to turn off all wells at once. This option allows you to

reactivate all of the wells at the previous setting by pressing (5).

Preheat Function:

1. Push (13) either before or after setting individual well. The unit will

operate on HIGH for 45 minutes and then revert to the previously

selected setting. If (4) is pushed while in pre-heat mode, (6) will

display the HIGH indicator light #9 and the light for the level previously

selected.

2. Push (13) a second time to remove the unit from preheat mode.

Set Clock:

NOTE: the clock does not need to be set for normal operation.
1. Push (8) to set hour. PM is indicated by a light in the upper right hand

corner of the window.

2. Push (9) to set minute.

Set Wells for Auto Mode:

NOTE: This can only be used with the auto START/STOP program.
1. Push (14) SET/HEAT/DISPLAY switch. “A” will appear in the left half

of the display window (7).

2. Push (2) INDIVIDUAL WELL SET/HEAT/DISPLAY switch for wells

that are to be activated at the start time. Hold until desired setting is

reached.

3. Push (14) to program desired well settings.
Temperatures may be reset by repeating this procedure. Automatic

heat settings may be set while unit is operating. Once entered, heat