English – Vollrath Signature Server Milk Station User Manual
Page 5
![background image](/manuals/468459/5/background.png)
5
ENGLISH
O
peratOr
’
s
M
anual
d
iScontinued
t
ouch
P
anel
c
ontrol
f
eatureS
and
f
unction
The discontinued touch panel control features and function are described below.
1
11
15
13
6
12
16
14
8
9
10
2
4
5
7
3
Figure 5. Discontinued Touch Panel Control
1. Electronic control panel.
2. Individual well Start/Stop switch. Push and hold to turn individual well on
and set heat level. Push again to turn well off.
3. Well indicator light. Lights when well is activated.
4. Well temperature display switch. Push and hold to display heat setting
selected for each individual well.
5. Master Start/Stop switch. Push to turn off all the wells at one time. Green
light indicates that the master switch may be used to reactivate all the
wells at the previous setting.
6. Heat setting display. Red lights indicate setting selected.
7. Clock. Used for time of day setting and Start/Stop programming.
8. Hour Set.
9. Minute Set.
10. Automatic Programming Start switch. Push to activate auto Start/Stop
Program. Clock must be set and operating to use this function.
11. Auto Start set switch.
12. Auto Stop set switch.
13. Preheat switch. Sets automatic 45 minute preheat when in automatic
mode. When used outside of automatic mode, pressing the automatic
preheat switch will give a 45 minute preheat at the high setting and then
revert to the selected temperature. Press for one second to engage.
14. Automatic heat switch. Used to set well heat setting when using auto
mode.
15. Auto start time display. Push to display start time preset.
16. Auto stop time display. Push to display stop time preset.
Control Panel Operation (Refer to Touch
Panel control diagram)
Start/Set Wells:
1. Push (2) and hold until desired heat setting (6) is displayed. (3) lights to
indicate well is on.
2. Push (4) to display heat setting for well.
3. Repeat for remaining wells.
Stop/Turn off Wells:
1. Push (2) to turn off well. (3) turns off to indicate well is off
OR
2. Push (5) to turn off all wells at once. This option allows you to
reactivate all of the wells at the previous setting by pressing (5).
Preheat Function:
1. Push (13) either before or after setting individual well. The unit will
operate on HIGH for 45 minutes and then revert to the previously
selected setting. If (4) is pushed while in pre-heat mode, (6) will
display the HIGH indicator light #9 and the light for the level previously
selected.
2. Push (13) a second time to remove the unit from preheat mode.
Set Clock:
NOTE: the clock does not need to be set for normal operation.
1. Push (8) to set hour. PM is indicated by a light in the upper right hand
corner of the window.
2. Push (9) to set minute.
Set Wells for Auto Mode:
NOTE: This can only be used with the auto START/STOP program.
1. Push (14) SET/HEAT/DISPLAY switch. “A” will appear in the left half
of the display window (7).
2. Push (2) INDIVIDUAL WELL SET/HEAT/DISPLAY switch for wells
that are to be activated at the start time. Hold until desired setting is
reached.
3. Push (14) to program desired well settings.
Temperatures may be reset by repeating this procedure. Automatic
heat settings may be set while unit is operating. Once entered, heat
settings remain until changed or the power is interrupted.
- Signature Server Cashier Station Signature Server Frost Top Station Signature Server Entree Cart Signature Server Beverage Counter Signature Server Utility Station Signature ServerHot/Cold Food Station Signature Server Cold Food Station Signature Server NSF7 Cold Station Bain Marie Hot Station Signature Server Hot Food Base with Touch-Temp Panel Operator Manual Signature Server with Laminate or Corian Countertops