Revolabs Fusion Microphone System - Polycom VSX8000e User Manual
Revolabs Equipment
Revolabs Fusion™ Microphone System - Polycom VSX8000e Setup Guide
N
OTES AND
C
AUTIONS
:
This setup guide will guide you through the steps needed to properly connect a
Revolabs Fusion Microphone System to a Polycom VSX8000e video codec.
1. Connecting the Cables
2. Configuring the VSX8000e Video Codec
Note:
It is important to carefully follow these instructions in order and completely.
Otherwise your Fusion Microphone System and/or the video codec may not function
properly. Please read through these instructions completely before proceeding.
Contact Revolabs technical support if you have any questions.
Requirements for connecting systems:
1. Revolabs Fusion 4 or 8 Channel Microphone System
2. Polycom VSX8000e video codec
3. QTY 1 RCA-RCA male cable
4. QTY 1 Revolabs 07-POLHDX-01 Phoenix to RCA cable*
5. Amplified speakers
*P
OLYCOM
VSX
8000
SERIES VIDEO CODECS HAVE PHOENIX CONNECT ORS FOR LINE INPUT WHILE
R
EVOLABS
F
USION
PRODUCTS USE
RCA
CONNECTORS FOR AUDIO INPUT
/
OUTPUT
.
T
HE
R
EVOLABS
07-POLHDX-01
P
HOENIX
-
TO
-RCA
CABLE IS A PRE
-
FABRICATED CABLE WIT H THE APPROPRIATE CONNECTIONS
.
O
THERWISE
,
A TECHNICIAN COULD
SIMPLY CUT OFF THE ENDS OF A SECOND
RCA
CABLE AND CONNECT PER THIS DIAGRAM
(R
EFERENCED FROM THE
P
OLYCOM
I
NTEGRATOR
’
S
R
EFERENCE MANUAL FOR THE
VSX
S
ERIES
V
ERSION
8.7,
A
UGUST