13.3. Autozero function

The AUTOZERO function is implemented to assure precise scale’s
indications. The function automatically controls and corrects scale’s zero
indication.
When the function is enabled, the following measurement results are
compared in constant time intervals. If the following values differ less than
declared AUTOZERO range, e.g. 1 division, then the scale automatically
zeroes its indication and displays pictograms of stable measurement result

and precise zero –

.

When the AUTOZERO function is enabled, each measurement result starts
from precise zero point. There are, however, cases when autozero function
may disturb weighing process, like while very slow loading / pouring
weighed object on scale’s weighing platform. In such case, the zero
correcting system can also correct the actual mass indication of weighed
object.

Procedure:

• Enter submenu in accordance with point 11.2 of this user

manual, and:

AUTO

no

- autozero disabled

AUTO

YES - autozero enabled

Return to weighing:

See point - 11.2.2. – return to weighing.