BRIGHTNESS

Adjust display brightness by pressing and holding the left BRIGHT

key.

MAXIMUM or WIND DIRECTION DISPLAY

MAXIMUM WIND SPEED GUST or numerical WIND DIRECTION

appears during operation depending on Right Display Window

(dSP) parameter setting. Maximum gust may be reset during normal

operation by pressing and holding the RESET key for 1 second.

REMOTE DISPLAYS

The Marine Wind Tracker may be configured as a remote display by

setting the Sensor Input for serial input (InP=SEr) and connecting

the RS-485 terminals to a source providing a $WIMWV NMEA

wind speed and direction string. This may be any valid NMEA

source including another Wind Tracker operating as a master,

a Young wind sensor or interface sending the NMEA string, or a

shipboard system.

With a Marine Wind Tracker as the NMEA source, use these settings:

MASTER: Sensor InP = any non-serial device.

REMOTE: Sensor InP = SEr

Connect one master with up to 16 remote displays via RS-485

terminals as shown in wiring diagrams. Remote Marine Wind

Trackers display exactly the same information as the master

including alarm states. MAX RESET and all display features are

controlled by the master unit only. Brightness can be adjusted

independently at each Marine Wind Tracker display.

VOLTAGE OUTPUTS

Calibrated voltage outputs for wind speed and direction are updated

16 times per second. Wind Speed 0-100 m/s = 0.00 to 5.00 VDC.

Wind Direction may be scaled for either 0-360 or 0-540 degrees =

0.00 to 5.00 VDC by setting the Direction (dir) parameter.

4-20 mA INPUTS

The Wind Tracker accepts 4-20 mA Line Driver inputs with either

0-50 m/s or 0-100 m/s scaling (Ldi and Ld2 input settings). Connect

as shown in wiring diagram. The back-panel switch labeled 4-20

mA must be in the UP position. 24VDC power is recommended

for most 4-20 mA installations.

POWER CONNECTIONS

The Marine Wind Tracker operates from 12 to 30 VDC. Power

may be connected via the coaxial jack or terminals. See wiring

diagrams for examples.

ERROR MESSAGES

Ldi

Err

4-20 mA (line driver) signal is missing or outside

an acceptable range. Verify connections, signal,

and 4-20 mA switch in UP position.

SEr

Err

Unit set to receive RS-485 serial signal (inP=SEr

or 09), but no serial data detected. Verify NMEA

source is working. Verify connections.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model 06206 Wind Tracker

The undersigned hereby declares on behalf of R. M.

Young Company that the above-referenced product, to

which this declaration relates, is in conformity with the

provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager

CE COMPLIANCE

This product complies with European CE EMC Directive.
Shielded cable must be used.

WARRANTY

The Wind Tracker is warranted to be free of defects in materials

and construction for a period of 12 months from date of purchase.

Coverage is limited to repair or replacement of defective unit.

SPECIFICATIONS

Size:

144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in)

Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in)

Sensors:

Wind Monitor-MA (05), Wind Monitor (05),

Wind Monitor HD (Hd), Wind Monitor-SE (SEr),

Ultrasonic Anemometer (SEr), Wind Monitor-JR

(04), Wind Sentry (03), Wind Monitor HD (Hd)

Accuracy:

±0.6% Full Scale

NMEA Serial Input & Output:

$WIMWV, ddd, R, sss, u, A*c

ddd wind direction in degrees

sss wind speed (ss.s for m/s)

u units (N knots, K km/hr, M m/s, S statute mph)

c NMEA checksum

Other inputs: 4-20 mA (0-360 deg, Ldi 0-50 m/s, Ld2 0-100 m/s)

Other outputs: 0-5 VDC = 0-360° or 0-540°

0-5 VDC = 0-100 m/s

Alarm Relays: Normally Open contacts for WS and WD

Contact rating 24 VAC or 30 VDC maximum

5A resistive, 2A inductive maximum

Input Power: 12-30 VDC, 3.5 W

Weight:

1.0 lb (0.45 kg) without AC adapter