Accurate wind measurements require proper instrument placement.

Eddies from trees, buildings, or other structures can greatly influence

wind speed and direction observations. To get meaningful data for

most applications, locate the instrument well above or upwind from

obstructions. As a general rule, the air flow around a structure is

disturbed to twice the height of the structure upwind, six times the

height downwind, and up to twice the height of the structure above

ground. For some applications it may not be practical or necessary to

meet these requirements.

Initial installation is most easily done with two people; one to adjust

the instrument position and the other to observe the indicating device.

After initial installation, the instrument can be removed and returned

to its mounting without realigning the vane since the orientation ring

preserves the wind direction reference. Install the Wind Monitor

following these steps:

1. MOUNT WIND MONITOR

a) Place orientation ring on mounting post. Do Not tighten

band clamp yet. Orientation ring may be omitted when portable

tripod is used.

b) Place Wind Monitor on mounting post. Do Not tighten band

clamp yet.

2. CONNECT SENSOR CABLE.

a) Refer to diagram W05501L located at back of manual.

3. ALIGN VANE

a) Connect instrument to indicator.

b) Choose a known wind direction reference point on the

horizon.

c) Sighting down instrument centerline, point nose cone at

reference point on horizon.

d) While holding vane in position, slowly turn base until

indicator shows proper value.

e) Tighten mounting post band clamp.

f) Engage orientation ring indexing pin in notch at instrument

base.

g) Tighten orientation ring band clamp.

CALIBRATION CHECK

The Wind Monitor IS is fully calibrated before shipment and should

require no adjustments. Periodic calibration checks are desirable and

may be necessary if the instrument is used in programs which require

auditing of sensor performance.

WIND DIRECTION

Place the instrument on a Young Model 18112 Vane Angle Bench

Stand. Connect the instrument to a signal conditioning circuit

which indicates wind direction. Move the vane to various angular

orientations on the Vane Angle Bench Stand and observe the Wind

Monitor output. Indicated vane angle should agree with actual angle

within ±3°. If measuring current output, use the following formula:

Note that while the sensor mechanically rotates through a full 360°,

the active region of the sensor ends at 355°. This means that the

highest obtainable reading occurs at 19.8 mA.

Remove the plastic nut on the propeller shaft. Install the propeller on

the shaft with the serial number of the propeller facing forward (into

the wind). The instrument is aligned, balanced and fully calibrated

before shipment; however, it should be checked both mechanically

and electrically before installation. The vane and propeller should

easily rotate 360° without friction. Check vane balance by holding

the instrument base so the vane surface is horizontal. It should have

near neutral torque without any particular tendency to rotate. A slight

imbalance will not degrade performance.

INSTALLATION

PROPER ELECTRICAL CONNECTION IS CRITICAL

FOR SAFE USE IN HAZARDOUS LOCATIONS.

FAILURE TO DO SO COULD RESULT IN INJURY TO PERSONS

OR PROPERTY DAMAGE.

AN APPROVED INSTRINSICALLY SAFE BARRIER

MUST BE USED.

REFER TO WIRING DIAGRAM FOR CONNECTION DETAILS.

FOLLOW BARRIER MANUFACTURER'S GUIDELINES FOR

CORRECT INSTALLATION.

OBSERVE NEC CODES FOR WIRING IN HAZARDOUS

LOCATIONS OR EQUIVALENT.

The Wind Monitor IS must be connected through an approved

Intrinsically Safe barrier or its equivalent. Examples of approved

barriers include the following models from MTL (www.mtl-inst.com):

MTL 7087+

Passive diode barrier with resistors

MTL 7106

Diode barrier with active electronics

MTL 7206

Diode barrier with active electronics

MTL 5041

Isolated barrier with active electronics

MTL 5044

2-ch version of MTL5041

Entity Parameters for the Wind Monitor IS are as follows:

Vmax

= 30 VDC

Imax

= 100 mA

Li

= 0.0 uH

Ci

= 0.01 uF

Any approved barrier may be used provided that its specifications and

the wiring connections fulfill the following relationship:

Vmax

> Voc

Imax

> Isc

La

> Li + Lw

Ca

> Ci + Cw

Where:

Vmax = 30 VDC Max Open Circuit Voltage of 05501LM

Imax = 100 mA Max Short Circuit Current of 05501LM

Li

= 0.0 uH Inductance of 05501LM

Ci

= 0.01 uF Capacitance of 05501LM

Lw

= Connecting Wire Inductance

Cw

= Connecting Wire Capacitance

Voc

= Maximum Open Circuit Voltage of IS Barrier

Isc

= Maximum Short Circuit Current of IS Barrier

La

= Maximum Allowed Inductance of IS Barrier

Ca

= Maximum Allowed Capacitance of IS Barrier

×

+

=