beautypg.com

0 specifications, 0 introduction, 0 initial checkout – Young Ultrasonic Anemometer Voltage and Serial Output Model 85000 User Manual

Page 4: Ultrasonic anemometer

background image

Page 1

85000-90

MODEL 85000

ULTRASONIC ANEMOMETER

1.0 SPECIFICATIONS

WIND SPEED

Range:

0-70 m/s (156 mph)

Resolution:

0.1 m/s

Accuracy:

0 to 30 m/s, ±2% or 0.1m/s

30 to 70 m/s, ±3%

WIND DIRECTION

Azimuth Range:

0-360 degrees

Resolution:

1 degree

Accuracy:

± 2 degrees

SERIAL OUTPUT

Type:

RS-232, RS-485, SDI-12

Formats:

ASCII Text (polled and continuous)

RMYT (Wind Tracker)

NMEA

SDI-12 (v1.3)

Baud Rates:

1200, 4800, 9600, and 38400 baud

ANALOG VOLTAGE OUTPUT

Polar

Wind Speed:

0 to 5000 mV (0 to 100 m/s)

Wind Direction:

0 to 5000 mV (0 to 360° or 0 to 540°)

Cartesian (UV)

U and V:

0 to 5000 mV (-100 m/s to +100 m/s)

GENERAL

Output rate:

1 Hz typical (selectable)

Power Supply:

9 to 16 VDC,

150 mA max

Dimensions:

34 cm high x 17 cm wide

Weight:

0.7 kg (1.5 lb)

Shipping Weight: 1.6 kg (3.5 lb)

2.0 INTRODUCTION

The YOUNG 85000 Ultrasonic Anemometer is a 2-axis, no-

moving-parts wind sensor. It is ideal for general meteorological

applications requiring accurate and reliable measurement.

The sensor features wide operating range, compact size, easy

installation and low power operation. Analog and digital signal

outputs are available in several popular formats.

The 85000 measures wind based on the transit time of ultrasonic

pulses between four transducers. Air flow alters the transit

time which is used to calculate flow velocity. Wind direction is

determined from relative velocities along each acoustic path.

Measurement results are available as calibrated voltage

output signals or serial data using RS-232, RS-485, or SDI-12

connections. Continuous output or polled operation may be used.

Serial formats may be selected for direct connection to YOUNG

Wind Tracker displays, marine NMEA systems, SDI-12 data

loggers, and ASCII serial communication programs.

Operating parameter options are selected using a simple setup

program provided. All 85000 settings are stored internally in non-

volatile memory.

The sensor is constructed using UV-stabilized thermoplastic,

stainless steel, and anodized aluminum for superior environmental

resistance. It is easily mounted on standard 1 inch (IPS) pipe.

An orientation ring preserves mounting position when the sensor

is removed.

3.0 INITIAL CHECKOUT

Carefully unpack the unit and inspect for physical damage. Any

damage should be reported to the shipper. The 85000 arrives fully

calibrated and ready to use. As supplied, the sensor is configured

as follows:

FACTORY DEFAULT CONFIGURATION:

Serial Output:

- RMYT Format

- RS-232

- RS-485 Output Only

- 9600 baud

Analog Voltage Outputs:

- Channel V1: Wind Speed

0-5000 mV = 0-100 m/sec

- Channel V2: Wind Direction

0-5000mV = 0-360 Deg

These settings will permit direct serial connection to the Young

Model 06201 Wind Tracker and connection of the voltage outputs

to a voltage measuring device or datalogger. For other available

serial or voltage output configurations refer to the appropriate

sections of the manual.

A simple operational check of the sensor may be performed as

follows: (Requires Model 06201 Wind Tracker)

3.1 Remove junction box cover and connect power and

signal wires to terminals as indicated in WIRING

CONNECTIONS (APPENDIX A). Supply voltage must

be 9 to 16 VDC.