Technical data and intended use – WIKA 232.36 User Manual
Page 6
![background image](/manuals/465675/6/background.png)
6
Temperature Class of the
ambient atmosphere
(ignition temperature)
Maximum permissible medium temperature
(in the pressure system)
Model 1.0
Models 3
(dry gauges)
Models 33
(liquid filled gauges)
T 6 (> 85 °C)
+70 °C
+70 °C
+70 °C
T 5 (> 100 °C)
+80 °C
+85 °C
+85 °C
T 4 (> 135 °C)
+80 °C
+10 °C
+100 °C
T 3 (> 00 °C)
+80 °C
+185 °C
+100 °C
T (> 300 °C)
+80 °C
+00 °C
+100 °C
T 1 (> 455 °C)
+80 °C
+00 °C
+100 °C
064
46 07/
009 GB/D/F
GB
WIKA Operating instructions pressure gauges Model with 831 per ATEX
Operating Temperature
Ambient: -5 … +60 °C (with inductive contacts in safety pattern version
Models 831.XX-SN up to -40 °C)
Attention: Footnote 1) under table 1 must be absolutely taken into account!
Medium: see table 1
Attention! In the case of gaseous substances, the temperature may increase
due to compression warming. In these cases it may be necessary to throttle
the rate of change of pressure or reduce the permissible temperature of the
pressure medium.
Table 1: Permissible medium temperature (only mechanical part)
1) The permissible uppper ambient temperature for the electrical components is determined by the
electrical connection values and the ignition temperature of the ambient gases, vapours and dusts.
Therefore the maximum permissible ambient temperatures specified in the EC-type examination
certificates for slot-type sensors and SN sensors must be observed as well. The
lower of these
two values is to be considered the maximum permissible ambient temperature!
Installation
In order to ensure that with Model 3X pressure can be safely and reliably
vented through the case back, a distance of at least 5 mm must be left free
behind the case!
In order to avoid any additional heating, the instruments must not be
exposed to direct solar irradiation while in operation!
With filled versions the ventilating valve (pressure ranges
≤10 bar) at the top
of the case must be opened prior to commissioning!
3. Technical data and intended use