1 storing/recalling setups, Storing/recalling setups, Section 7.1 – Kramer Electronics SP-12HD User Manual
Page 15

Operating the SP-12HD HD-SDI Processor
13
13
display shows the current level (in digits). “0” corresponds
to normal level (“NORM”)
• Press the + button or - button once to gradually increase or
decrease the current level by one unit (the 7-segment
display shows the new level)
To increase or decrease the current level rapidly, press and
hold the + button or - button, continuously
• To set “NORM” of the current level rapidly, press and hold
down the + button and – button together, continuously, the
7-segment display shows “0”
To end the rapid adjustment, release the + button or –
button
• To undo the adjustment, press the appropriate button one
more time. The appropriate button no longer blinks
• To save result of adjustment, press the STORE button
twice
• To store result of adjustment in other setup #, press the
STORE button once and then select a setup # between 1
and 16 by pressing the + and – button. Then press STORE
button one more time
• If the result of the adjustment equals “NORM”, then the
appropriate button no longer illuminates, otherwise this
button continues to illuminate in main mode
7.1
Storing/Recalling Setups
You can store and recall up to 16 setups (or adjustments) in non-volatile
memory, using the STORE and RECALL buttons together with the + and –
buttons.
To store
• Press the STORE button and then select a setup # between 1 and
16 by pressing the + and – buttons (the current settings are saved
to that setup #)
a setup, do the following:
• Then press STORE button one more time
To recall a setup, do the following:
1 The 7-segment display starts to quickly scan the range. When it stops running, it has reached the maximum or minimum,
respectively
2 Storing a new setup over a previous setup # replaces the previous setup #