11 kramer protocol 3000, 1 switching protocols, Kramer protocol 3000 – Kramer Electronics VS-88SDI User Manual
Page 30: Switching protocols
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol 3000
26
11
Kramer Protocol 3000
The VS-88SDI can be operated using serial commands from a PC, remote
controller, or touch screen. The unit communicates using the default Kramer
Protocol 3000 but can also use Kramer Protocol 2000.
This section describes:
• How to switch between Protocol 3000 and Protocol 2000 (see
• Kramer Protocol 3000 syntax (see section
• Kramer Protocol 3000 commands (see section
11.1 Switching Protocols
Protocols can be switched either from the front panel buttons or by
transmitting protocol commands.
To switch protocols using the front panel buttons:
• To choose Protocol 2000, press LOCK and OUT 2 at the same time
• To choose the Protocol 3000, press LOCK and OUT 3 at the same
time
To switch protocols using protocol commands:
• To switch from Protocol 3000 to Protocol 2000, send the following
command:
#P2000
• To switch from Protocol 2000 to Protocol 3000, send the following
command:
0x38, 0x80, 0x83, 0x81
Note: If you are using Kramer’s Windows
®
-based control software
it
operates only with Protocol 2000. If the VS-88SDI is set to Protocol 3000,
it automatically switches to Protocol 2000.
1 Download the latest software from our Web site at
http://www.kramerelectronics.com