beautypg.com

Kramer Electronics VP-728 User Manual

Page 66

background image

VP-728 - VP-728 Communication Protocol

61

61

Control Type

Function Parameter

Description

Set

Get

1: On

0

-

118

N/A

Advance Input Mode: Save

0

1

119

512~3071

Advance Output Mode: HT

0

1

120

32~(HS-48)

Advance Output Mode: HW

0

1

121

80~(HT-HA-12)

Advance Output Mode: HS

0

1

122

640~1920

<= (HT-92)

Advance Output Mode: HA

0

1

123

0: Negative polarity

1: Positive polarity

Advance Output Mode: HP

0

1

124

384~2047

Advance Output Mode: VT

0

1

125

2~(HS-13)

Advance Output Mode: VW

0

1

126

15~(VT-VA-1)

Advance Output Mode: VS

0

1

127

480~1200

<= (VT-16)

Advance Output Mode: VA

0

1

128

0: Negative polarity

1: Positive polarity

Advance Output Mode: VP

0

1

129

25 < OCLK < 165

Advance Output Mode: OCLK(Integer)

0

1

130

25 < OCLK < 165

Advance Output Mode: OCLK(Decimal)

0

-

131

N/A

Advance Output Mode: Save

0

-

132

N/A

Advance Output Mode: Set Current

0

-

133

N/A

Volume Up

0

-

134

n/a

Volume Down

0

1

135

0: Follow Output

1: Follow Input

HDCP Setting

0

1

136

0:Custom1

1:Custom2

2:Custom3

3:Custom4

Advance Input Mode: Custom Input

0

1

137

0:Custom1

1:Custom2

2:Custom3

3:Custom4

Advance Output Mode: Custom Output

0

1

138

0: Off

1: On

Overscan

0

1

139

0: Seamless

1: Fast

Switching Mode

0

1

140

0: Manual

1: Auto

Auto Image Mode

0

-

141

N/A

Slideshow Start

0

-

142

N/A

Slideshow Stop

0

-

143

N/A

Slideshow Pause

0

-

144

N/A

Slideshow Next

0

-

145

N/A

Slideshow Previous

0

1

146

0: Min

1: Low

2: Mid

Slideshow