VP-728 - Audio Flash Memory Upgrade
45
45
9. Click Run.
After each stage of the operation is completed, the check-box for that stage
becomes colored green.
See also the blue progress indicator on the status bar
10. When the operation is completed, all 4 check-boxes will be colored green
and the status bar message: Memory Verify Pass appears:
If an error message: “Not Finished” shows, click Run again
Figure 31: Atmel – Flip Window (Operation Completed)
11. Close the “Atmel – Flip” window.
12. Disconnect the power on the VP-728.
13. If required, disconnect the rear panel AUDIO PROG. terminal block
connector on the VP-728.
14. Release the rear panel AUDIO PROG. button, using a small screwdriver.
15. Connect the power to the VP-728.
Upon initialization, the new VP-728
audio software version shows in the
Information menu (see
).