18

TROUBLESHOOTING

NOTES

1.

Please note that if the output signal is disturbed or

interrupted by very strong external electromagnetic

interference, it should return and stabilize when such

interference ends. If not, turn the power switch off and on

again to reset the machine.

2.

If the recommended actions still do not result in satisfactory

operation, please consult your KRAMER Dealer.

Power and Indicators

Problem

Remedy

No Power

1.

Confirm that rocker switch is in “ON” position, and red LED is

illuminated.

2.

Confirm that power connections are secured at the amplifier and at the

receptacle. Make sure the receptacle is active, outputting the proper

mains voltage.

3.

If there is still no power, check the fuse. Remove power cord from the

AC outlet and from the machine and then, using a flat head screwdriver,

remove the fuse holder located directly below the power connector.

Confirm that the fuse is good by looking at the wire connected to the

ends of the fuse. If the wire is broken, replace the fuse with another,

with the same value.

Video Signal

Problem

Remedy

No video at the

output device,

regardless of

input selected.

1.

Confirm that your sources and output device are powered on and

connected properly. Video signals at the input of your amplifier should

be of an identical signal format at the output of your source. Video

signals at the output of your amplifier should be of an identical signal

format as at the input of your display or recorder.

2.

Confirm that any other amplifiers in the signal path have the proper input

and/or output selected.

3.

Use a Video Tester to test the video path leading to/from your amplifier.

Video level is too

high or too dim.

1.

The amplifiers in this manual (except for the VM-1044 and VM-54)

have termination switches on each input. Verify that the video line is

well matched through 75 impedance, otherwise it results in a video

level that is too high or too dim when looping is performed and the

termination switches are not in proper position.

2.

Confirm that the connecting cables are of high quality, properly built and

terminated with 75 BNC connectors. Check level controls located on your

source input device or output display or recorder.