beautypg.com

Warnings – SawStop 1.75HP User Manual

Page 9

background image

SawStop 10” Professional Cabinet Saw 7

5. Professional Cabinet Saw Model PCS175 in its standard confi guration is intended for use on a 110-120V

supply circuit that has an outlet that looks like the one illustrated in Sketch A below.

A temporary adapter, which looks like the adapter illustrated in Sketch B and C, may be used to connect this plug
to a 2 pole receptacle as shown in Sketch B if a properly grounded outlet is not available. The temporary adapter
should be used only until a properly grounded outlet can be installed by a qualifi ed electrician. This adapter
is not permitted in Canada. The green-colored rigid ear, lug, and the like, extending from the adapter must be
connected to a permanent ground such as a properly grounded outlet box.

6.

Professional Cabinet Saw Model PCS175 re-wired for 208-230V power is intended for use on a circuit that has
an outlet that looks like the one illustrated in Sketch D. The saw has a grounding plug that looks like the plug
illustrated in Sketch D. Make sure the saw is connected to an outlet having the same confi guration as the plug.
No adapter is available or should be used with this saw. If the saw must be reconnected for use on a different
type of electric circuit, the reconnection should be made by qualifi ed service personnel; and after reconnection,
the saw should comply with all local codes and ordinances.

!

WARNINGS

Sketch D

grounding pin

grounding pin

Sketch A

Sketch B

cover of grounded

outlet box

metal screw

cover of grounded

outlet box

Sketch C

grounding

means

adapter

adapter