beautypg.com

RMS Technologies R325 DRIVER W/PDT User Manual

Page 18

background image

RMS Technologies

Page 18

Version 1.21

R325 Single Axis Driver Manual

08/23/2007

Driver to Motor Cable AWG Table

1 Amp (Peak)

5 Amp (Peak)

Length

(Feet) 10 25 50 75 100 Length

(Feet) 10 25 50 75 100

Minimum

AWG 20 20 18 18 16 Minimum

AWG 16 16 14 12 12

2 Amp (Peak)

6 Amp (Peak)

Length

(Feet) 10 25 50 75 100 Length

(Feet) 10 25 50 75 100

Minimum

AWG 20 18 16 14 14 Minimum

AWG 14 14 14 12 12

3 Amp (Peak)

7 Amp (Peak)

Length

(Feet) 10 25 50 75 100 Length

(Feet) 10 25 50 75 100

Minimum

AWG 18 16 14 12 12 Minimum

AWG 12 12 12 12 12

4 Amp (Peak)

Length

(Feet) 10 25 50 75 100

Minimum

AWG 18 16 14 12 12

Driver to Motor Supply Cable Wire Size

NOTE: These recommendations will provide optimal protection against EMI and RFI. The
actual cable type, wire gauge, shield type and filtering devices used are dependent on the

customer’s application and system.

NOTE: Always use Shielded/Twisted Pairs for the Driver DC Supply Cable, the AC Supply

Cable and the Driver to Motor Cable.