Configure the R325 using the DIP Switch
R325 DIP Switch Settings
Run Current
Function
SW1
SW2
SW3
SW4
0.3A ON ON ON ON
0.4A
OFF
ON
ON
ON
0.5A ON OFF ON ON
0.6A
OFF
OFF
ON
ON
0.8A ON ON OFF ON
1.0A
OFF
ON
OFF
ON
1.2A ON OFF OFF ON
1.4A
OFF
OFF
OFF
ON
1.6A ON ON ON OFF
1.8A
OFF
ON
ON
OFF
2.0A ON OFF ON OFF
2.2A
OFF
OFF
ON
OFF
2.4A ON ON OFF OFF
2.6A
OFF
ON
OFF
OFF
2.8A ON OFF OFF OFF
3.0A
OFF
OFF
OFF
OFF
WARNING: Current of 2.7 Amp and above REQUIRES an additional heatsink, make sure
the temperature of the bracket does not exceed 45° C
Hold Current (Percent of Run Current)
Function
SW5
SW6
0% ON ON
33%
OFF
ON
66% ON OFF
100%
OFF
OFF
Step Resolution
Function
SW7
SW8
SW9
SW10
Full
Step*
OFF OFF OFF OFF
2X
ON
OFF
OFF
OFF
4X ON ON OFF
OFF
8X
ON
OFF
ON
OFF
16X ON ON ON OFF
32X
ON
OFF
OFF
ON
64X ON ON OFF ON
128X
ON
OFF
ON
ON
256X ON ON ON ON
*The power must be turned OFF when switching in and out of Full Step mode.
Notes:
1. Installing a jumper on JP1 pins 9 and 10 runs the factory test routine